FD.io DC Testbed Specifications #
Purpose #
This note includes specification of the physical testbed infrastructure hosted by LFN FD.io CSIT project.
Server Management #
Addressing #
Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a Management port, which are connected to two different VLANs.
LOM (IPMI) VLAN #
- Subnet: 10.30.50.0/24
- Gateway: 10.30.50.1
- Broadcast: 10.30.50.255
- DNS1: 199.204.44.24
- DNS2: 199.204.47.54
Management VLAN #
- Subnet: 10.30.51.0/24
- Gateway: 10.30.51.1
- Broadcast: 10.30.51.255
- DNS1: 199.204.44.24
- DNS2: 199.204.47.54
To access these hosts, VPN connection is required.
Testbeds Overview #
Summary List #
#. Type Purpose SUT TG #TB #SUT #TG #skx #ps1 #rng #tx2 #tsh #alt #clx #zn2 #icx #snr #spr #icxd
1. 1-Node-Skylake nomad skx na 5 5 0 5 0 0 0 0 0 0 0 0 0 0 0
2. 1-Node-Cascadelake nomad clx na 4 4 0 0 0 0 0 0 0 4 0 0 0 0 0
3. 1-Node-AmpereAltra nomad alt na 4 4 0 0 0 0 0 0 4 0 0 0 0 0 0
4. 2-Node-IxiaPS1L47 tcp skx ps1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0
5. 2-Node-Cascadelake perf clx clx 3 3 3 0 0 0 0 0 0 6 0 0 0 0 0
6. 2-Node-ThunderX2 perf tx2 skx 1 1 .5 .5 0 0 1 0 0 0 0 0 0 0 0
7. 2-Node-Icelake perf icx icx 4 4 4 0 0 0 0 0 0 0 0 8 0 0 0
8. 3-Node-Rangeley perf rng skx 1 3 1 0 0 2 0 0 0 0 0 0 0 0 0
9. 3-Node-Taishan perf tsh skx 1 2 .5 .5 0 0 0 2 0 0 0 0 0 0 0
10. 3-Node-Altra perf alt icx 1 2 1 0 0 0 0 0 2 0 0 1 0 0 0
11. 2-Node-Zen2 perf zn2 zn2 1 1 1 0 0 0 0 0 0 0 2 0 0 0 0
12. 3-Node-Icelake perf icx icx 2 4 2 0 0 0 0 0 0 0 0 6 0 0 0
13. 3-Node-SnowRidge perf snr icx 1 2 .5 0 0 0 0 0 0 0 0 .5 2 0 0
14. 2-Node-SapphireRapids perf spr spr 4 4 4 0 0 0 0 0 0 0 0 0 0 8 0
15. 1-Node-SapphireRapids nomad spr na 4 4 0 0 0 0 0 0 0 0 0 0 0 4 0
16. 3-Node-IcelakeD perf icxd icx 4 6 1 0 0 0 0 0 0 0 0 1 0 0 4
Totals: 39 48 19.5 7 1 2 1 2 6 10 2 16.5 2 12 4
1-Node-Skylake Xeon Intel (1n-skx) #
Each 1-Node-Skylake testbed includes one SUT (Server-Type-B2) with NIC ports connected back-to-back (Server Types). Used for FD.io VPP_Device functional driver tests.
1-Node-Altra Arm Ampere (1n-alt) #
Each 1-Node-Altra testbed includes one SUT (Server-Type-E25) with NIC ports connected back-to-back (Server Types). Used for FD.io VPP_Device functional driver tests.
1-Node-Skylake Xeon Intel (1n-spr) #
Each 1-Node-SapphireRapids testbed includes one SUT (Server-Type-H7) with NIC ports connected back-to-back (Server Types). Used for FD.io VPP_Device functional driver tests.
2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1) #
Each 2-Node-IxiaPS1L47 testbed includes one SUT (Server-Type-B1) and one TG (Ixia PSOne appliance) with 10GE interfaces connected in a 2-node circular topology (Server Types). Used for FD.io TCP/IP and HTTP performance tests.
2-Node-Cascadelake Xeon Intel (2n-clx) #
Each 2-Node-Cascadelake testbed includes one SUT (Server-Type-C2) and one TG (Server-Type-C3) connected in a 2-node circular topology (Server Types). Used for FD.io performance tests.
2-Node-Zen2 EPYC AMD (2n-zn2) #
Each 2-Node-Zen2 testbed includes one SUT (Server-Type-D1) and one TG (Server-Type-D2) connected in a 2-node circular topology (Server Types). Used for FD.io performance tests.
2-Node-ThunderX2 Arm Marvell (2x-tx2) #
Each 2-Node-ThunderX2 testbed includes one SUT (Server-Type-E22) and one TG (Server-Type-E31) connected in a 2-node circular topology (Server Types). Used for FD.io performance tests.
2-Node-Icelake Xeon Intel (2n-icx) #
Each 2-Node-Icelake testbed includes one SUT (Server-Type-F1) and one TG (Server-Type-F2) connected in a 2-node circular topology (Server Types). Used for FD.io performance tests.
3-Node-Rangeley Atom Testbeds #
Each 3-Node-Rangeley testbed includes two SUTs (Server-Type-B5) and one TG (Server-Type-2) connected in a 3-node circular topology (Server Types). Used for FD.io performance tests.
3-Node-TaiShan Arm Huawei (3n-tsh) #
Each 3-Node-TaiShan testbed includes two SUTs (Server-Type-E21) and one TG (Server-Type-E31) connected in a 3-node circular topology (Server Types). Used for FD.io performance tests.
3-Node-Altra Arm Ampere (3n-alt) #
Each 3-Node-Altra testbed includes two SUTs (Server-Type-E23) and one TG (Server-Type-E32) connected in a 3-node circular topology (Server Types). Used for FD.io performance tests.
3-Node-Icelake Xeon Intel (3n-icx) #
Each 3-Node-Icelake testbed includes two SUTs (Server-Type-F3) and one TG (Server-Type-F3) connected in a 3-node circular topology (Server Types). Used for FD.io performance tests.
3-Node-IcelakeD Xeon Intel (3n-icxd) #
Each 3-Node-IcelakeD testbed includes two SUTs (Server-Type-I1) and one numa of TG (Server-Type-F5) connected in a 3-node circular topology (Server Types). Used for FD.io performance tests.
3-Node-SnowRidge Atom Intel (3n-snr) #
Each 3-Node-SnowRidge testbed includes two SUTs (Server-Type-G1) and one TG (Server-Type-F5) connected in a 3-node circular topology (Server Types). Used for FD.io performance tests.
2-Node-SapphireRapids Xeon Intel (2n-spr) #
Each 2-Node-SapphireRapids testbed includes one SUT (Server-Type-H5) and one TG (Server-Type-H6) connected in a 2-node or 3-node circular topology (Server Types). Used for FD.io performance tests.
Testbed Naming Convention #
Following naming convention is used within this page to specify physical connectivity and wiring across defined CSIT testbeds:
- testbedname: testbedN.
- hostname:
- traffic-generator: tN-tgW.
- system-under-testX: tN-sutX.
- portnames:
- tN-tgW-cY/pZ.
- tN-sutX-cY/pZ.
- where:
- N - testbed number.
- tgW - server acts as traffic-generator with W index.
- sutX - server acts as system-under-test with X index.
- Y - PCIe slot number denoting a NIC card number within the host.
- Z - port number on the NIC card.
Server Types #
FD.io CSIT lab contains following server types:
-
Server-Type-B1: Purpose - Skylake Xeon hosts for FD.io builds and data processing.
- Quantity: 2
- Physical connectivity:
- IPMI and host management ports.
- Main HW configuration:
- Chassis: SuperMicro SYS-7049GP-TRT.
- Motherboard: SuperMicro X11DPG-QT.
- Processors: 2* Intel Platinum 8180 2.5 GHz.
- RAM Memory: 16* 16GB DDR4-2666MHz.
- Disks: 2* 1.6TB 6G SATA SSD.
- NICs configuration:
- Numa0: (x16, x16, x16 PCIe3.0 lanes)
- PCIe Slot2 18:00.xx: empty.
- PCIe Slot4 3b:00.xx: empty.
- PCIe Slot9 5e:00.xx: empty.
- Numa1: (x16, x16, x16 PCIe3.0 lanes)
- PCIe Slot6 86:00.xx: empty.
- PCIe Slot8 af:00.xx: empty.
- PCIe Slot10 d8:00.xx: empty.
- Numa0: (x16, x16, x16 PCIe3.0 lanes)
-
Server-Type-B2: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests.
- Quantity: 2.
- Physical connectivity:
- IPMI and host management ports.
- NIC ports connected into 1-node topologies.
- Main HW configuration:
- Chassis: SuperMicro SYS-7049GP-TRT.
- Motherboard: SuperMicro X11DPG-QT.
- Processors: 2* Intel Platinum 8180 2.5 GHz.
- RAM Memory: 16* 16GB DDR4-2666MHz.
- Disks: 2* 1.6TB 6G SATA SSD.
- NICs configuration:
- Numa0: (x16, x16, x16 PCIe3.0 lanes)
- PCIe Slot2 18:00.xx: x710-4p10GE Intel.
- PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
- PCIe Slot9 5e:00.xx: empty.
- Numa1: (x16, x16, x16 PCIe3.0 lanes)
- PCIe Slot6 86:00.xx: e810-2CQDA2-2p100GE Intel.
- PCIe Slot8 af:00.xx: e810-2CQDA2-2p100GE Intel.
- PCIe Slot10 d8:00.xx: empty.
- Numa0: (x16, x16, x16 PCIe3.0 lanes)
-
Server-Type-B7: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests.
- Quantity: 1.
- Physical connectivity:
- Host management interface: 10/100/1000-BaseT.
- 8-port 10GE SFP+ integrated NIC.
- Main HW configuration:
- Chassis: PS10GE4NG.
- Motherboard: SuperMicro X11DPG-QT.
- Processors: Quad-Core, Intel Processor.
- HW accelerators: FPGA offload.
- RAM Memory: 64GB.
- Disks: 1 * 1 TB, Enterprise Class, High MTBF.
- Physical Interfaces: 4 * 10GE SFP+.
- Operating System: Native IxOS.
- Interface configuration:
- Port-1: 10GE SFP+.
- Port-2: 10GE SFP+.
- Port-3: 10GE SFP+.
- Port-4: 10GE SFP+.
-
Server-Type-B8: Purpose - Skylake Xeon SUT for TCP/IP host stack tests.
- Quantity: 1.
- Physical connectivity:
- IPMI and host management ports.
- NIC ports.
- Main HW configuration:
- Chassis: SuperMicro SYS-7049GP-TRT.
- Motherboard: SuperMicro X11DPG-QT.
- Processors: 2* Intel Platinum 8180 2.5 GHz.
- RAM Memory: 16* 16GB DDR4-2666MHz.
- Disks: 2* 1.6TB 6G SATA SSD.
- NICs configuration:
- Numa0: (x16, x16, x16 PCIe3.0 lanes)
- PCIe Slot2 18:00.xx: x710-4p10GE Intel.
- PCIe Slot4 3b:00.xx: empty.
- PCIe Slot9 5e:00.xx: empty.
- Numa1: (x16, x16, x16 PCIe3.0 lanes)
- PCIe Slot6 86:00.xx: empty.
- PCIe Slot8 af:00.xx: empty.
- PCIe Slot10 d8:00.xx: empty.
- Numa0: (x16, x16, x16 PCIe3.0 lanes)
-
Server-Type-C2: Purpose - Cascadelake Xeon SUT for FD.io performance testing.
- Quantity: 3
- Physical connectivity:
- IPMI and host management ports.
- NIC ports connected into 2-node testbed topologies.
- Main HW configuration:
- Chassis: SuperMicro SYS-7049GP-TRT.
- Motherboard: SuperMicro X11DPG-QT.
- Processors: 2* Intel Gold 6252N 2.3 GHz.
- RAM Memory: 12* 16GB DDR4-2933.
- Disks: 2* 1.92TB SATA SSD.
- NICs configuration:
- Numa0: (x16, x16, x16 PCIe3.0 lanes)
- PCIe Slot2 18:00.xx: x710-4p10GE Intel.
- PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
- PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
- Numa1: (x16, x16, x16 PCIe3.0 lanes)
- PCIe Slot6 86:00.xx: e810-2p100GE Intel.
- PCIe Slot8 af:00.xx: empty.
- PCIe Slot10 d8:00.xx: empty.
- Numa0: (x16, x16, x16 PCIe3.0 lanes)
-
Server-Type-C3: Purpose - Cascadelake Xeon TG for FD.io performance testing.
- Quantity: 3.
- Physical connectivity:
- IPMI and host management ports.
- NIC ports connected into 2-node testbed topologies.
- Main HW configuration:
- Chassis: SuperMicro SYS-7049GP-TRT.
- Motherboard: SuperMicro X11DPG-QT.
- Processors: 2* Intel Platinum 8280 2.7 GHz.
- RAM Memory: 12* 16GB DDR4-2933.
- Disks: 2* 1.92TB SATA SSD.
- NICs configuration:
- Numa0: (x16, x16, x16 PCIe3.0 lanes)
- PCIe Slot2 18:00.xx: x710-4p10GE Intel.
- PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
- PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
- Numa1: (x16, x16, x16 PCIe3.0 lanes)
- PCIe Slot6 86:00.xx: ConnectX5-2p100GE Mellanox.
- PCIe Slot8 af:00.xx: ConnectX5-2p100GE Mellanox.
- PCIe Slot10 d8:00.xx: empty.
- Numa0: (x16, x16, x16 PCIe3.0 lanes)
-
Server-Type-C4: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing.
- Quantity: 4.
- Physical connectivity:
- IPMI and host management ports.
- no NIC ports, standalone setup.
- Main HW configuration:
- Chassis: SuperMicro 1029P-WTRT.
- Motherboard: SuperMicro X11DDW-NT.
- Processors: 2* Intel Platinum 8280 2.7 GHz.
- RAM Memory: 12* 16GB DDR4-2933.
- Disks: 4* 1.92TB SATA SSD.
- NICs configuration:
- Numa0: (x16, x16, x16 PCIe3.0 lanes)
- PCIe Slot2 18:00.xx: empty.
- PCIe Slot4 3b:00.xx: empty.
- PCIe Slot9 5e:00.xx: empty.
- Numa1: (x16, x16, x16 PCIe3.0 lanes)
- PCIe Slot6 86:00.xx: empty.
- PCIe Slot8 af:00.xx: empty.
- PCIe Slot10 d8:00.xx: empty.
- Numa0: (x16, x16, x16 PCIe3.0 lanes)
-
Server-Type-D1: Purpose - Zen2 EPYC SUT for FD.io performance testing.
- Quantity: 1.
- Physical connectivity:
- IPMI and host management ports.
- NIC ports connected into 2-node testbed topologies.
- Main HW configuration:
- Chassis: SuperMicro AS-1114S-WTRT
- Processors: 1* AMD EPYC 7532 2.4 GHz.
- RAM Memory: 8* 32GB DDR4-2933.
- Disks: 1* 1TB SATA SSD.
- NICs configuration:
- Numa0: (x16, x16, x16 PCIe3.0 lanes)
- PCIe Slot1 01:00.xx: x710-4p10GE Intel.
- PCIe Slot2 41:00.xx: xxv710-da2-2p25GE Intel.
- PCIe Slot3 81:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
- Numa0: (x16, x16, x16 PCIe3.0 lanes)
-
Server-Type-D2: Purpose - Zen2 EPYC TG for FD.io performance testing.
- Quantity: 1.
- Physical connectivity:
- IPMI and host management ports.
- NIC ports connected into 2-node testbed topologies.
- Main HW configuration:
- Chassis: SuperMicro AS-1114S-WTRT
- Processors: 1* AMD EPYC 7532 2.4 GHz.
- RAM Memory: 8* 32GB DDR4-2933.
- Disks: 1* 1TB SATA SSD.
- NICs configuration:
- Numa0: (x16, x16, x16 PCIe3.0 lanes)
- PCIe Slot1 01:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
- PCIe Slot2 41:00.xx: x710-4p10GE Intel.
- PCIe Slot3 81:00.xx: xxv710-da2 2p25GE Intel.
- Numa0: (x16, x16, x16 PCIe3.0 lanes)
-
Server-Type-E21: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing.
- Quantity: 2.
- Physical connectivity:
- IPMI(?) and host management ports.
- NIC ports connected into 3-node topology.
- Main HW configuration:
- Chassis: Huawei TaiShan 2280.
- Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72
- RAM Memory: 8* 16GB DDR4-2400MT/s
- Disks: 1* 4TB SATA HDD
- NICs configuration:
- PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox.
- PCIe Slot6 11:00.xx: x520-2p10GE Intel.
-
Server-Type-E22: Purpose - ThunderX2 Arm Marvell SUT for FD.io performance testing.
- Quantity: 1.
- Physical connectivity:
- IPMI and host management ports.
- NIC ports connected into 2-node topologies.
- Main HW configuration:
- Chassis: Gigabyte R181-T90 1U
- Motherboard: MT91-FS1
- Processors: 2* ThunderX2 ARMv8 CN9975 2.0 GHz
- RAM Memory: 4* 32GB RDIMM
- Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
- NICs configuration:
- Numa0:
- no cards
- Numa1:
- PCIe Slot18 91:00.xx: XL710-QDA2-2p40GE Intel.
- Numa0:
-
Server-Type-E23: Purpose - Altra Arm Ampere SUT for FD.io performance testing.
- Quantity: 2.
- Physical connectivity:
- IPMI and host management ports.
- NIC ports connected into 3-node topologies.
- Main HW configuration:
- Chassis: WIWYNN Mt.Jade Server System B81.030Z1.0007 2U
- Motherboard: Mt.Jade Motherboard
- Processors: 2* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1)
- Processor Signature: Implementor 0x41, Variant 0x3, Architecture 15, Part 0xd0c, Revision 1
- RAM Memory: 16* 8GB DDR4-3200MT/s
- Disks: 2* 960GB SSD Samsung M.2 NVMe PM983
- NICs configuration:
- Numa0: (x16, x16 PCIe4.0 lanes)
- PCIe Slot1 0004:04:00.x: xl710-QDA2-2p40GE Intel.
- PCIe Slot8 0001:00:00.x: ConnectX6-2p100GE Mellanox.
- Numa1:
- no cards.
- Numa0: (x16, x16 PCIe4.0 lanes)
-
Server-Type-E24: Purpose - Altra Arm Ampere for FD.io build.
- Quantity: 2.
- Physical connectivity:
- IPMI and host management ports.
- Main HW configuration:
- Chassis: Gigabyte R152-P30-00 1U
- Motherboard: MP32-AR1-00
- Processors: 1* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1)
- Processor Signature: Implementor 0x0a, Variant 0x1, Architecture 6, Part 0x000, Revision 1
- RAM Memory: 12* 16GB DDR4-3200MT/s
- Disks: 1* 960GB SSD Samsung M.2 NVMe PM983
-
Server-Type-E25: Purpose - Altra Arm Ampere SUT for FD.io VPP_Device functional tests.
- Quantity: 2.
- Physical connectivity:
- IPMI and host management ports.
- NIC ports connected into 1-node topologies.
- Main HW configuration:
- Chassis: Gigabyte E252-P30-00 2U
- Motherboard: MP32-AR1-00
- Processors: 1* Ampere(R) Altra(R) M128-30 Processor (Neoverse N1)
- Processor Signature: Implementor 0x41 (Arm), Variant 0x3, Architecture 0xf, Part 0xd0c (neoverse-n1), Revision 0x1
- RAM Memory: 32* 32GB DDR4-3200MT/s
- Disks: 2* 960GB SSD Samsung M.2 NVMe PM9A3
- NICs configuration:
- Numa0:
- PCIe Slot0 0000:01:00.xx: XL710-QDA2-2p40GE Intel.
- PCIe Slot1 0001:01:00.xx: ConnectX6-2p100GE Mellanox.
- PCIe Slot2 0002:03:00.xx: ConnectX5-2p10/25GE Mellanox.
- Numa1:
- PCIe Slot3 0003:02:00.xx: XL710-QDA2-2p40GE Intel.
- PCIe Slot5 0005:02:00.xx: ConnectX5-2p10/25GE Mellanox.
- Numa0:
-
Server-Type-E31: Purpose - Skylake Xeon Shared TG for FD.io performance testing.
- Quantity: 1.
- Physical connectivity:
- IPMI and host management ports.
- NIC ports connected into 2-node and 3-node topologies.
- Main HW configuration:
- Chassis: SuperMicro SYS-7049GP-TRT.
- Motherboard: SuperMicro X11DPG-QT.
- Processors: 2* Intel Platinum 8180 2.5 GHz.
- RAM Memory: 16* 16GB DDR4-2666MHz.
- Disks: 2* 1.6TB 6G SATA SSD.
- NICs configuration:
- Numa0: (x16, x16, x16 PCIe3.0 lanes)
- PCIe Slot2 18:00.xx: x710-4p10GE Intel.
- PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
- PCIe Slot9 5e:00.xx: empty.
- Numa1: (x16, x16, x16 PCIe3.0 lanes)
- PCIe Slot6 86:00.xx: empty.
- PCIe Slot8 af:00.xx: xl710-QDA2-2p40GE Intel.
- PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
- Numa0: (x16, x16, x16 PCIe3.0 lanes)
-
Server-Type-E32: Purpose - Icelake Xeon Shared TG for FD.io performance testing.
- Quantity: 1.
- Physical connectivity:
- IPMI and host management ports.
- NIC ports connected into 2-node and/or 3-node testbed topologies.
- Main HW configuration:
- Chassis: SuperMicro SYS-740GP-TNRT.
- Motherboard: Super X12DPG-QT6.
- Processors: 2* Intel Platinum 8358 2.6 GHz.
- RAM Memory: 16* 16GB DDR4-3200.
- Disks: 2* 960GB SATA SSD.
- NICs configuration:
- Numa0: (x16, x16, x16 PCIe4.0 lanes)
- PCIe Slot2 4b:00.xx: xxv710-DA2-2p25GE Intel.
- PCIe Slot4 31:00.xx: xl710-QDA2-2p40GE Intel.
- PCIe Slot9 ff:00.xx: empty.
- Numa1: (x16, x16, x16 PCIe4.0 lanes)
- PCIe Slot6 ca:00.xx: empty.
- PCIe Slot8 b1:00.xx: e810-2CQDA2-2p100GE Intel.
- PCIe Slot10 ff:00.xx: empty.
- Numa0: (x16, x16, x16 PCIe4.0 lanes)
-
Server-Type-F1: Purpose - Icelake Xeon SUT for FD.io performance testing.
- Quantity: 4.
- Physical connectivity:
- IPMI and host management ports.
- NIC ports connected into 2-node topology.
- Main HW configuration:
- Chassis: SuperMicro SYS-740GP-TNRT.
- Motherboard: Super X12DPG-QT6.
- Processors: 2* Intel Platinum 8358 2.6 GHz.
- RAM Memory: 16* 16GB DDR4-3200.
- Disks: 2* 960GB SATA SSD.
- NICs configuration:
- Numa0: (x16, x16, x16 PCIe4.0 lanes)
- PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
- PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
- PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel.
- Numa1: (x16, x16, x16 PCIe4.0 lanes)
- PCIe Slot6 86:00.xx: empty.
- PCIe Slot8 af:00.xx: ConnectX7-2p200GE Mellanox.
- PCIe Slot10 d8:00.xx: empty.
- Numa0: (x16, x16, x16 PCIe4.0 lanes)
-
Server-Type-F2: Purpose - Icelake Xeon TG for FD.io performance testing.
- Quantity: 4.
- Physical connectivity:
- IPMI and host management ports.
- NIC ports connected into 2-node testbed topologies.
- Main HW configuration:
- Chassis: SuperMicro SYS-740GP-TNRT.
- Motherboard: Super X12DPG-QT6.
- Processors: 2* Intel Platinum 8358 2.6 GHz.
- RAM Memory: 16* 16GB DDR4-3200.
- Disks: 2* 960GB SATA SSD.
- NICs configuration:
- Numa0: (x16, x16, x16 PCIe4.0 lanes)
- PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
- PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
- PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel.
- Numa1: (x16, x16, x16 PCIe4.0 lanes)
- PCIe Slot6 86:00.xx: e810-2CQDA2-2p100GE Intel.
- PCIe Slot8 af:00.xx: ConnectX7-2p200GE Mellanox.
- PCIe Slot10 d8:00.xx: empty.
- Numa0: (x16, x16, x16 PCIe4.0 lanes)
-
Server-Type-F3: Purpose - Icelake Xeon TG or SUT for FD.io performance testing.
- Quantity: 6.
- Physical connectivity:
- IPMI and host management ports.
- NIC ports connected into 3-node testbed topologies.
- Main HW configuration:
- Chassis: SuperMicro SYS-740GP-TNRT.
- Motherboard: Super X12DPG-QT6.
- Processors: 2* Intel Platinum 8358 2.6 GHz.
- RAM Memory: 16* 16GB DDR4-3200.
- Disks: 2* 960GB SATA SSD.
- NICs configuration:
- Numa0: (x16, x16, x16 PCIe4.0 lanes)
- PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
- PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
- PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel.
- Numa1: (x16, x16, x16 PCIe4.0 lanes)
- PCIe Slot6 86:00.xx: ConnectX6-2p100GE Mellanox.
- PCIe Slot8 af:00.xx: empty.
- PCIe Slot10 d8:00.xx: empty.
- Numa0: (x16, x16, x16 PCIe4.0 lanes)
-
Server-Type-F4: Purpose - Icelake Xeon TG for FD.io performance testing.
- Quantity: 3.
- Physical connectivity:
- IPMI and host management ports.
- NIC ports connected into 3-node testbed topologies.
- Main HW configuration:
- Chassis: SuperMicro SYS-740GP-TNRT.
- Motherboard: Super X12DPG-QT6.
- Processors: 2* Intel Platinum 8358 2.6 GHz.
- RAM Memory: 16* 16GB DDR4-3200.
- Disks: 2* 960GB SATA SSD.
- NICs configuration:
- Numa0: (x16, x16, x16 PCIe4.0 lanes)
- PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
- PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
- PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel.
- Numa1: (x16, x16, x16 PCIe4.0 lanes)
- PCIe Slot6 86:00.xx: ConnectX6-2p100GE Mellanox.
- PCIe Slot8 af:00.xx: empty.
- PCIe Slot10 d8:00.xx: empty.
- Numa0: (x16, x16, x16 PCIe4.0 lanes)
-
Server-Type-F5: Purpose - Icelake Xeon Shared TG for FD.io performance testing.
- Quantity: 2.
- Physical connectivity:
- IPMI and host management ports.
- NIC ports connected into 2-node and/or 3-node testbed topologies.
- Main HW configuration:
- Chassis: SuperMicro SYS-740GP-TNRT.
- Motherboard: Super X12DPG-QT6.
- Processors: 2* Intel Platinum 8358 2.6 GHz.
- RAM Memory: 16* 16GB DDR4-3200.
- Disks: 2* 960GB SATA SSD.
- NICs configuration:
- Numa0: (x16, x16, x16 PCIe4.0 lanes)
- PCIe Slot2 4b:00.xx: xxv710-DA2-2p25GE Intel.
- PCIe Slot4 31:00.xx: empty.
- PCIe Slot9 ff:00.xx: empty.
- Numa1: (x16, x16, x16 PCIe4.0 lanes)
- PCIe Slot6 ca:00.xx: e810-XXVDA4-4p25GE Intel.
- PCIe Slot8 b1:00.xx: e810-2CQDA2-2p100GE Intel.
- PCIe Slot10 ff:00.xx: empty.
- Numa0: (x16, x16, x16 PCIe4.0 lanes)
-
Server-Type-G1: Purpose - SnowRidge Atom SUT for FD.io performance testing.
- Quantity: 2
- Physical connectivity:
- IPMI and host management ports.
- NIC ports connected into 3-node testbed topology.
- Main HW configuration:
- Chassis: Intel JACOBSVILLE SDP.
- Motherboard: Intel JACOBSVILLE E63448-400.
- Processors: 1* Intel Atom P5362B 2.2 GHz.
- RAM Memory: 2* 16GB DDR4-2933.
- Disks: ?* ? SATA SSD.
- NICs configuration:
- Numa0: (x16, PCIe3.0 lane)
- PCIe BuiltIn ec:00.xx: e810-XXVDA4-4p25GE Intel.
- Numa0: (x16, PCIe3.0 lane)
-
Server-Type-H1: Purpose - SapphireRapids Xeon SUT for FD.io full system performance testing.
- Quantity: 1.
- Physical connectivity:
- IPMI and host management ports.
- NIC ports connected into 3-numa-node testbed topologies.
- Main HW configuration:
- Chassis: SuperMicro SYS-741GE-TNRT.
- Motherboard: Super X13DEG-QT-P.
- Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP.
- RAM Memory: 16* 32GB DDR5-4800.
- Disks: 2* 960GB SATA SSD.
- NICs configuration:
- Numa0: (x16, x16, x16 PCIe5.0 lanes)
- PCIe Slot2 18:00.xx: ConnectX7-2p200GE Nvidia.
- PCIe Slot4 3b:00.xx: ConnectX7-2p200GE Nvidia.
- PCIe Slot10 5e:00.xx: ConnectX7-2p200GE Nvidia.
- Numa1: (x16, x16, x16 PCIe5.0 lanes)
- PCIe Slot7 86:00.xx: ConnectX7-2p200GE Nvidia.
- PCIe Slot9 af:00.xx: ConnectX7-2p200GE Nvidia.
- PCIe Slot11 d8:00.xx: ConnectX7-2p200GE Nvidia.
- Numa0: (x16, x16, x16 PCIe5.0 lanes)
-
Server-Type-H2: Purpose - SapphireRapids Xeon TG for FD.io full system performance testing.
- Quantity: 1.
- Physical connectivity:
- IPMI and host management ports.
- NIC ports connected into 3-numa-node testbed topologies.
- Main HW configuration:
- Chassis: SuperMicro SYS-741GE-TNRT.
- Motherboard: Super X13DEG-QT-P.
- Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP.
- RAM Memory: 16* 32GB DDR5-4800.
- Disks: 2* 960GB SATA SSD.
- NICs configuration:
- Numa0: (x16, x16, x16 PCIe5.0 lanes)
- PCIe Slot2 18:00.xx: ConnectX7-2p200GE Nvidia.
- PCIe Slot4 3b:00.xx: ConnectX7-2p200GE Nvidia.
- PCIe Slot10 5e:00.xx: ConnectX7-2p200GE Nvidia.
- Numa1: (x16, x16, x16 PCIe5.0 lanes)
- PCIe Slot7 86:00.xx: ConnectX7-2p200GE Nvidia.
- PCIe Slot9 af:00.xx: ConnectX7-2p200GE Nvidia.
- PCIe Slot11 d8:00.xx: empty.
- Numa0: (x16, x16, x16 PCIe5.0 lanes)
-
Server-Type-H3: Purpose - SapphireRapids Xeon SUT for FD.io performance testing.
- Quantity: 1.
- Physical connectivity:
- IPMI and host management ports.
- NIC ports connected into 3-numa-node testbed topologies.
- Main HW configuration:
- Chassis: SuperMicro SYS-741GE-TNRT.
- Motherboard: Super X13DEG-QT-P.
- Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP.
- RAM Memory: 16* 32GB DDR5-4800.
- Disks: 2* 960GB SATA SSD.
- NICs configuration:
- Numa0: (x16, x16, x16 PCIe5.0 lanes)
- PCIe Slot2 18:00.xx: e810-2CQDA2-2p100GE Intel.
- PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
- PCIe Slot10 5e:00.xx: empty.
- Numa1: (x16, x16, x16 PCIe5.0 lanes)
- PCIe Slot7 86:00.xx: e810-2CQDA2-2p100GE Intel.
- PCIe Slot9 af:00.xx: e810-XXVDA4-4p25GE Intel.
- PCIe Slot11 d8:00.xx: empty.
- Numa0: (x16, x16, x16 PCIe5.0 lanes)
-
Server-Type-H4: Purpose - SapphireRapids Xeon TG for FD.io performance testing.
- Quantity: 1.
- Physical connectivity:
- IPMI and host management ports.
- NIC ports connected into 3-numa-node testbed topologies.
- Main HW configuration:
- Chassis: SuperMicro SYS-741GE-TNRT.
- Motherboard: Super X13DEG-QT-P.
- Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP.
- RAM Memory: 16* 32GB DDR5-4800.
- Disks: 2* 960GB SATA SSD.
- NICs configuration:
- Numa0: (x16, x16, x16 PCIe5.0 lanes)
- PCIe Slot2 18:00.xx: e810-2CQDA2-2p100GE Intel.
- PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
- PCIe Slot10 5e:00.xx: empty.
- Numa1: (x16, x16, x16 PCIe5.0 lanes)
- PCIe Slot7 86:00.xx: empty.
- PCIe Slot9 af:00.xx: empty.
- PCIe Slot11 d8:00.xx: empty.
- Numa0: (x16, x16, x16 PCIe5.0 lanes)
-
Server-Type-H5: Purpose - SapphireRapids Xeon SUT for FD.io performance testing.
- Quantity: 2.
- Physical connectivity:
- IPMI and host management ports.
- NIC ports connected into 2-node testbed topologies.
- Main HW configuration:
- Chassis: SuperMicro SYS-741GE-TNRT.
- Motherboard: Super X13DEG-QT-P.
- Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP.
- RAM Memory: 16* 32GB DDR5-4800.
- Disks: 2* 960GB SATA SSD.
- NICs configuration:
- Numa0: (x16, x16, x16 PCIe5.0 lanes)
- PCIe Slot2 3d:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
- PCIe Slot4 2c:00.xx: e810-2CQDA2-2p100GE Intel.
- PCIe Slot10 17:00.xx: e810-XXVDA4-4p25GE Intel.
- Numa1: (x16, x16, x16 PCIe5.0 lanes)
- PCIe Slot7 86:00.xx: empty.
- PCIe Slot9 af:00.xx: empty.
- PCIe Slot11 d8:00.xx: empty.
- Numa0: (x16, x16, x16 PCIe5.0 lanes)
-
Server-Type-H6: Purpose - SapphireRapids Xeon TG for FD.io performance testing.
- Quantity: 2.
- Physical connectivity:
- IPMI and host management ports.
- NIC ports connected into 2-node testbed topologies plus loopbacks in Numa1 for TG self-test.
- Main HW configuration:
- Chassis: SuperMicro SYS-741GE-TNRT.
- Motherboard: Super X13DEG-QT-P.
- Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP.
- RAM Memory: 16* 32GB DDR5-4800.
- Disks: 2* 960GB SATA SSD.
- NICs configuration:
- Numa0: (x16, x16, x16 PCIe5.0 lanes)
- PCIe Slot2 18:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
- PCIe Slot4 3b:00.xx: e810-2CQDA2-2p100GE Intel.
- PCIe Slot10 5e:00.xx: e810-XXVDA4-4p25GE Intel.
- Numa1: (x16, x16, x16 PCIe5.0 lanes)
- PCIe Slot7 86:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
- PCIe Slot9 af:00.xx: e810-2CQDA2-2p100GE Intel.
- PCIe Slot11 d8:00.xx: empty.
- Numa0: (x16, x16, x16 PCIe5.0 lanes)
-
Server-Type-H7: Purpose - SapphireRapids SUT for FD.io VPP_Device functional tests.
- Quantity: 2.
- Physical connectivity:
- IPMI and host management ports.
- NIC ports connected into 1-node topologies.
- Main HW configuration:
- Chassis: SuperMicro SYS-741GE-TNRT.
- Motherboard: Super X13DEG-QT-P.
- Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP.
- RAM Memory: 16* 32GB DDR5-4800.
- Disks: 2* 960GB SATA SSD.
- NICs configuration:
- Numa0: (x16, x16, x16 PCIe5.0 lanes)
- PCIe Slot2 18:00.xx: e810-2CQDA2-2p100GE Intel.
- PCIe Slot4 3b:00.xx: e810-2CQDA2-2p100GE Intel.
- PCIe Slot10 5e:00.xx: empty.
- Numa1: (x16, x16, x16 PCIe5.0 lanes)
- PCIe Slot7 86:00.xx: empty.
- PCIe Slot9 af:00.xx: empty.
- PCIe Slot11 d8:00.xx: empty.
- Numa0: (x16, x16, x16 PCIe5.0 lanes)
-
Server-Type-I1: Purpose - IcelakeD Xeon SUT for FD.io performance testing.
- Quantity: 4
- Physical connectivity:
- IPMI and host management ports.
- NIC ports connected into 3-node testbed topology.
- Main HW configuration:
- Chassis: SuperMicro SYS-110D-20C-FRDN8TP.
- Motherboard: Super X12SDV-20C-SPT8F.
- Processors: 1* Intel Xeon D-2796NT.
- RAM Memory: 4* 32GB DDR4-3200 MEM-DR432MD-ER32.
- Disks: 1* 960GB SATA SSD HDS-25T0.
- NICs configuration:
- Numa0: (x16, PCIe4.0 lane)
- PCIe BuiltIn ??:00.xx: e810-XXVDA2-2p25GE Intel.
- Numa0: (x16, PCIe4.0 lane)
Testbeds Configuration #
1-Node-Skylake (1n-skx) #
- SUT [Server-Type-B2]:
- testbedname: testbed11.
- hostname: s1-t11-sut1.
- IPMI IP: 10.30.50.47
- Host IP: 10.30.51.50
- portnames:
- s1-t11-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
- s1-t11-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
- s1-t11-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
- s1-t11-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
- s1-t11-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
- s1-t11-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
- s1-t11-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
- s1-t11-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
- s1-t11-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
- s1-t11-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
- s1-t11-sut1-c8/p1 - 100GE-port1 e810-2p100GE.
- s1-t11-sut1-c8/p2 - 100GE-port2 e810-2p100GE.
- SUT [Server-Type-B2]:
- testbedname: testbed12.
- hostname: s2-t12-sut1.
- IPMI IP: 10.30.50.48
- Host IP: 10.30.51.51
- portnames:
- s2-t12-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
- s2-t12-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
- s2-t12-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
- s2-t12-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
- s2-t12-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
- s2-t12-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
- s2-t12-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
- s2-t12-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
- s2-t12-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
- s2-t12-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
- s2-t12-sut1-c8/p1 - 100GE-port1 e810-2p100GE.
- s2-t12-sut1-c8/p2 - 100GE-port2 e810-2p100GE.
1-Node-Altra (1n-alt) #
- SUT [Server-Type-E25]:
- testbedname: testbed13
- hostname: s70-t13-sut1
- IPMI IP: 10.30.50.70
- Host IP: 10.30.51.70
- portnames:
- s70-t13-sut1-c0/p1 - 40GE-port1 XL710-QDA2-2p40GE.
- s70-t13-sut1-c0/p2 - 40GE-port2 XL710-QDA2-2p40GE.
- s70-t13-sut1-c1/p1 - 100GE-port1 ConnectX6-2p100GE Mellanox.
- s70-t13-sut1-c1/p2 - 100GE-port2 ConnectX6-2p100GE Mellanox.
- s70-t13-sut1-c2/p1 - 25GE-port1 ConnectX5-2p10/25GE Mellanox.
- s70-t13-sut1-c2/p2 - 25GE-port2 ConnectX5-2p10/25GE Mellanox.
- s70-t13-sut1-c3/p1 - 40GE-port1 XL710-QDA2-2p40GE.
- s70-t13-sut1-c3/p2 - 40GE-port2 XL710-QDA2-2p40GE.
- s70-t13-sut1-c5/p1 - 25GE-port1 ConnectX5-2p10/25GE Mellanox.
- s70-t13-sut1-c5/p2 - 25GE-port2 ConnectX5-2p10/25GE Mellanox.
- SUT [Server-Type-E25]:
- testbedname: testbed14
- hostname: s71-t14-sut1
- IPMI IP: 10.30.50.71
- Host IP: 10.30.51.71
- portnames:
- s71-t14-sut1-c0/p1 - 40GE-port1 XL710-QDA2-2p40GE.
- s71-t14-sut1-c0/p2 - 40GE-port2 XL710-QDA2-2p40GE.
- s71-t14-sut1-c1/p1 - 100GE-port1 ConnectX6-2p100GE Mellanox.
- s71-t14-sut1-c1/p2 - 100GE-port2 ConnectX6-2p100GE Mellanox.
- s71-t14-sut1-c2/p1 - 25GE-port1 ConnectX5-2p10/25GE Mellanox.
- s71-t14-sut1-c2/p2 - 25GE-port2 ConnectX5-2p10/25GE Mellanox.
- s71-t14-sut1-c3/p1 - 40GE-port1 XL710-QDA2-2p40GE.
- s71-t14-sut1-c3/p2 - 40GE-port2 XL710-QDA2-2p40GE.
- s71-t14-sut1-c5/p1 - 25GE-port1 ConnectX5-2p10/25GE Mellanox.
- s71-t14-sut1-c5/p2 - 25GE-port2 ConnectX5-2p10/25GE Mellanox.
1-Node-SapphireRapids (1n-spr) #
- SUT [Server-Type-H7]:
- testbedname: testbed15.
- hostname: s30-t15-sut1.
- IPMI IP: 10.30.50.30
- Host IP: 10.30.51.31
- portnames:
- s30-t15-sut1-c1/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
- s30-t15-sut1-c1/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
- s30-t15-sut1-c2/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
- s30-t15-sut1-c2/p2 - 100GE-port1 e810-2CQDA2-2p100GE.
- SUT [Server-Type-H7]:
- testbedname: testbed16.
- hostname: s31-t16-sut1.
- IPMI IP: 10.30.50.31
- Host IP: 10.30.51.31
- portnames:
- s31-t16-sut1-c1/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
- s31-t16-sut1-c1/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
- s31-t16-sut1-c2/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
- s31-t16-sut1-c2/p2 - 100GE-port1 e810-2CQDA2-2p100GE.
2-Node-IxiaPS1L47 (2n-ps1) #
- SUT [Server-Type-B8]:
- testbedname: testbed25.
- hostname: s25-t25-sut1.
- IPMI IP: 10.30.50.58
- Host IP: 10.30.51.61
- portnames:
- s25-t25-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
- s25-t25-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
- s25-t25-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
- s25-t25-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
- TG [Server-Type-B7]:
- testbedname: testbed25.
- hostname: s26-t25-tg1.
- IPMI IP: 10.30.50.59
- Host IP: 10.30.51.62
- portnames:
- s26-t25-tg1-p1 - 10GE-port1.
- s26-t25-tg1-p2 - 10GE-port2.
- s26-t25-tg1-p3 - 10GE-port3.
- s26-t25-tg1-p4 - 10GE-port4.
2-Node-Cascadelake (2n-clx) #
- SUT [Server-Type-C2]:
- testbedname: testbed27.
- hostname: s33-t27-sut1.
- IPMI IP: 10.30.55.18
- Host IP: 10.32.8.18
- portnames:
- s33-t27-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
- s33-t27-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
- s33-t27-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
- s33-t27-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
- s33-t27-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- s33-t27-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- s33-t27-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
- s33-t27-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
- s33-t27-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
- s33-t27-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
- TG [Server-Type-C3]:
- testbedname: testbed27.
- hostname: s34-t27-tg1.
- IPMI IP: 10.30.55.19
- Host IP: 10.32.8.19
- portnames:
- s34-t27-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
- s34-t27-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
- s34-t27-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
- s34-t27-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- s34-t27-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- s34-t27-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- s34-t27-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE.
- s34-t27-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE.
- s38-t27-tg1-c8/p1 - 100GE-port1 ConnectX5-2p100GE.
- s38-t27-tg1-c8/p2 - 100GE-port2 ConnectX5-2p100GE.
- s34-t27-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
- s34-t27-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
- SUT [Server-Type-C2]:
- testbedname: testbed28.
- hostname: s35-t28-sut1.
- IPMI IP: 10.30.55.20
- Host IP: 10.32.8.20
- portnames:
- s35-t28-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
- s35-t28-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
- s35-t28-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
- s35-t28-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
- s35-t28-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- s35-t28-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- s35-t28-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
- s35-t28-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
- s35-t28-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
- s35-t28-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
- TG [Server-Type-C3]:
- testbedname: testbed28.
- hostname: s36-t28-tg1.
- IPMI IP: 10.30.55.21
- Host IP: 10.32.8.21
- portnames:
- s36-t28-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
- s36-t28-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
- s36-t28-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
- s36-t28-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- s36-t28-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- s36-t28-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- s36-t28-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE.
- s36-t28-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE.
- s38-t28-tg1-c8/p1 - 100GE-port1 ConnectX5-2p100GE.
- s38-t28-tg1-c8/p2 - 100GE-port2 ConnectX5-2p100GE.
- s36-t28-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
- s36-t28-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
- SUT [Server-Type-C2]:
- testbedname: testbed29.
- hostname: s37-t29-sut1.
- IPMI IP: 10.30.55.22
- Host IP: 10.32.8.22
- portnames:
- s37-t29-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
- s37-t29-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
- s37-t29-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
- s37-t29-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
- s37-t29-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- s37-t29-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- s37-t29-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
- s37-t29-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
- s37-t29-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
- s37-t29-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
- TG [Server-Type-C3]:
- testbedname: testbed29.
- hostname: s38-t29-tg1.
- IPMI IP: 10.30.55.23
- Host IP: 10.32.8.23
- portnames:
- s38-t29-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
- s38-t29-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
- s38-t29-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
- s38-t29-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- s38-t29-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- s38-t29-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- s38-t29-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE.
- s38-t29-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE.
- s38-t29-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
- s38-t29-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
2-Node-Zen2 (2n-zn2) #
- SUT [Server-Type-D1]:
- testbedname: testbed210.
- hostname: s60-t210-sut1.
- IPMI IP: 10.30.55.24
- Host IP: 10.32.8.24
- portnames:
- s60-t210-sut1-c1/p1 - 10GE-port1 x710-4p10GE.
- s60-t210-sut1-c1/p2 - 10GE-port2 x710-4p10GE.
- s60-t210-sut1-c1/p3 - 10GE-port3 x710-4p10GE.
- s60-t210-sut1-c1/p4 - 10GE-port4 x710-4p10GE.
- s60-t210-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- s60-t210-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- s60-t210-sut1-c3/p1 - 100GE-port1 ConnectX5-2p100GE.
- s60-t210-sut1-c3/p2 - 100GE-port2 ConnectX5-2p100GE.
- TG [Server-Type-D2]:
- testbedname: testbed210.
- hostname: s61-t210-tg1.
- IPMI IP: 10.30.55.25
- Host IP: 10.32.8.25
- portnames:
- s61-t210-tg1-c1/p1 - 100GE-port1 ConnectX5-2p100GE.
- s61-t210-tg1-c1/p2 - 100GE-port2 ConnectX5-2p100GE.
- s61-t210-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
- s61-t210-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
- s61-t210-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
- s61-t210-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- s61-t210-tg1-c3/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- s61-t210-tg1-c3/p2 - 25GE-port2 xxv710-DA2-2p25GE.
2-Node-ThunderX2 (2x-tx2) #
- SUT [Server-Type-E22]:
- testbedname: testbed211.
- hostname: s27-t211-sut1.
- IPMI IP: 10.30.50.69
- Host IP: 10.30.51.69
- portnames:
- s27-t211-sut1-c18/p1 - 40GE-port1 xl710-QDA2-2p40GE.
- s27-t211-sut1-c18/p2 - 40GE-port2 xl710-QDA2-2p40GE.
- TG [Server-Type-E31]:
- testbedname: testbed33 and testbed211.
- hostname: s19-t33t211-tg1.
- IPMI IP: 10.30.50.46
- Host IP: 10.30.51.49
- portnames:
- s19-t33t211-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
- s19-t33t211-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
- s19-t33t211-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
- s19-t33t211-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- s19-t33t211-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- s19-t33t211-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- s19-t33t211-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE.
- s19-t33t211-tg1-c8/p2 - 40GE-port2 xl710-QDA2-2p40GE.
- s19-t33t211-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
- s19-t33t211-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
- s19-t33t211-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
- s19-t33t211-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
2-Node-Icelake (2n-icx) #
- SUT [Server-Type-F1]:
- testbedname: testbed212.
- hostname: s71-t212-sut1.
- IPMI IP: 10.30.50.81
- Host IP: 10.30.51.81
- portnames:
- s71-t212-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- s71-t212-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- s71-t212-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
- s71-t212-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
- s71-t212-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
- s71-t212-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
- s71-t212-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
- s71-t212-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
- s71-t212-sut1-c8/p1 - 200GE-port1 ConnectX7-2p200GE.
- s71-t212-sut1-c8/p2 - 200GE-port2 ConnectX7-2p200GE.
- TG [Server-Type-F2]:
- testbedname: testbed212.
- hostname: s72-t212-tg1.
- IPMI IP: 10.30.50.82
- Host IP: 10.30.51.82
- portnames:
- s72-t212-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- s72-t212-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- s72-t212-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
- s72-t212-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
- s72-t212-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
- s72-t212-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
- s72-t212-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
- s72-t212-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
- s72-t212-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
- s72-t212-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
- s72-t212-tg1-c8/p1 - 200GE-port1 ConnectX7-2p200GE.
- s72-t212-tg1-c8/p2 - 200GE-port2 ConnectX7-2p200GE.
- SUT [Server-Type-F1]:
- testbedname: testbed213.
- hostname: s83-t213-sut1.
- IPMI IP: 10.30.50.83
- Host IP: 10.30.51.83
- portnames:
- s83-t213-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- s83-t213-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- s83-t213-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
- s83-t213-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
- s83-t213-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
- s83-t213-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
- s83-t213-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
- s83-t213-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
- s83-t213-sut1-c8/p1 - 200GE-port1 ConnectX7-2p200GE.
- s83-t213-sut1-c8/p2 - 200GE-port2 ConnectX7-2p200GE.
- TG [Server-Type-F2]:
- testbedname: testbed213.
- hostname: s84-t213-tg1.
- IPMI IP: 10.30.50.84
- Host IP: 10.30.51.84
- portnames:
- s84-t213-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- s84-t213-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- s84-t213-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
- s84-t213-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
- s84-t213-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
- s84-t213-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
- s84-t213-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
- s84-t213-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
- s84-t213-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
- s84-t213-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
- s84-t213-tg1-c8/p1 - 200GE-port1 ConnectX7-2p200GE.
- s84-t213-tg1-c8/p2 - 200GE-port2 ConnectX7-2p200GE.
- SUT [Server-Type-F1]:
- testbedname: testbed214.
- hostname: s85-t214-sut1.
- IPMI IP: 10.30.50.85
- Host IP: 10.30.51.85
- portnames:
- s85-t214-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- s85-t214-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- s85-t214-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
- s85-t214-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
- s85-t214-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
- s85-t214-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
- s85-t214-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
- s85-t214-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
- s85-t214-sut1-c8/p1 - 200GE-port1 ConnectX7-2p200GE.
- s85-t214-sut1-c8/p2 - 200GE-port2 ConnectX7-2p200GE.
- TG [Server-Type-F2]:
- testbedname: testbed214.
- hostname: s86-t214-tg1.
- IPMI IP: 10.30.50.86
- Host IP: 10.30.51.86
- portnames:
- s86-t214-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- s86-t214-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- s86-t214-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
- s86-t214-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
- s86-t214-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
- s86-t214-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
- s86-t214-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
- s86-t214-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
- s86-t214-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
- s86-t214-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
- s86-t214-tg1-c8/p1 - 200GE-port1 ConnectX7-2p200GE.
- s86-t214-tg1-c8/p2 - 200GE-port2 ConnectX7-2p200GE.
- SUT [Server-Type-F1]:
- testbedname: testbed215.
- hostname: s87-t215-sut1.
- IPMI IP: 10.30.50.87
- Host IP: 10.30.51.87
- portnames:
- s87-t215-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- s87-t215-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- s87-t215-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
- s87-t215-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
- s87-t215-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
- s87-t215-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
- s87-t215-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
- s87-t215-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
- s87-t215-sut1-c8/p1 - 200GE-port1 ConnectX7-2p200GE.
- s87-t215-sut1-c8/p2 - 200GE-port2 ConnectX7-2p200GE.
- TG [Server-Type-F2]:
- testbedname: testbed215.
- hostname: s88-t215-tg1.
- IPMI IP: 10.30.50.88
- Host IP: 10.30.51.88
- portnames:
- s88-t215-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- s88-t215-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- s88-t215-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
- s88-t215-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
- s88-t215-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
- s88-t215-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
- s88-t215-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
- s88-t215-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
- s88-t215-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
- s88-t215-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
- s88-t215-tg1-c8/p1 - 200GE-port1 ConnectX7-2p200GE.
- s88-t215-tg1-c8/p2 - 200GE-port2 ConnectX7-2p200GE.
3-Node-Taishan (3n-tsh) #
- SUT [Server-Type-E21]:
- testbedname: testbed33.
- hostname: s17-t33-sut1.
- IPMI IP: 10.30.50.36
- Host IP: 10.30.51.36
- portnames:
- s17-t33-sut1-c6/p1 - 10GE-port1 x520-2p10GE.
- s17-t33-sut1-c6/p2 - 10GE-port2 x520-2p10GE.
- s17-t33-sut1-c4/p1 - 25GE-port1 cx4-2p25GE.
- s17-t33-sut1-c4/p2 - 25GE-port2 cx4-2p25GE.
- SUT [Server-Type-E21]:
- testbedname: testbed33.
- hostname: s18-t33-sut2.
- IPMI IP: 10.30.50.37
- Host IP: 10.30.51.37
- portnames:
- s18-t33-sut2-c6/p1 - 10GE-port1 x520-2p10GE.
- s18-t33-sut2-c6/p2 - 10GE-port2 x520-2p10GE.
- s18-t33-sut2-c4/p1 - 25GE-port1 cx4-2p25GE.
- s18-t33-sut2-c4/p2 - 25GE-port2 cx4-2p25GE.
- TG [Server-Type-E31]:
- testbedname: testbed33 and testbed211.
- hostname: s19-t33t211-tg1.
- IPMI IP: 10.30.50.46
- Host IP: 10.30.51.49
- portnames:
- s19-t33t211-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
- s19-t33t211-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
- s19-t33t211-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
- s19-t33t211-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- s19-t33t211-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- s19-t33t211-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- s19-t33t211-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE.
- s19-t33t211-tg1-c8/p2 - 40GE-port2 xl710-QDA2-2p40GE.
- s19-t33t211-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
- s19-t33t211-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
- s19-t33t211-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
- s19-t33t211-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
3-Node-Altra (3n-alt) #
- SUT [Server-Type-E23]:
- testbedname: testbed34.
- hostname: s62-t34-sut1.
- IPMI IP: 10.30.50.72
- Host IP: 10.30.51.72
- portnames:
- s62-t34-sut1-c1/p1 - 40GE-port1 xl710-QDA2-2p40GE.
- s62-t34-sut1-c1/p2 - 40GE-port2 xl710-QDA2-2p40GE.
- s62-t34-sut1-c8/p1 - 100GE-port1 ConnectX6-2p100GE.
- s62-t34-sut1-c8/p2 - 100GE-port2 ConnectX6-2p100GE.
- SUT [Server-Type-E23]:
- testbedname: testbed34.
- hostname: s63-t34-sut2.
- IPMI IP: 10.30.50.73
- Host IP: 10.30.51.73
- portnames:
- s63-t34-sut2-c1/p1 - 40GE-port1 xl710-QDA2-2p40GE.
- s63-t34-sut2-c1/p2 - 40GE-port2 xl710-QDA2-2p40GE.
- s63-t34-sut2-c8/p1 - 100GE-port1 ConnectX6-2p100GE.
- s63-t34-sut2-c8/p2 - 100GE-port2 ConnectX6-2p100GE.
- TG [Server-Type-E32]:
- testbedname: testbed34.
- hostname: s64-t34-tg1.
- IPMI IP: 10.30.50.74
- Host IP: 10.30.51.74
- portnames:
- s64-t34-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- s64-t34-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- s64-t34-tg1-c4/p1 - 40GE-port1 xl710-QDA2-2p40GE.
- s64-t34-tg1-c4/p2 - 40GE-port2 xl710-QDA2-2p40GE.
- s64-t34-tg1-c8/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
- s64-t34-tg1-c8/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
3-Node-Icelake (3n-icx) #
- SUT1 [Server-Type-F3]:
- testbedname: testbed37.
- hostname: s65-t37-sut1.
- IPMI IP: 10.30.50.75
- Host IP: 10.30.51.75
- portnames:
- s65-t37-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- s65-t37-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- s65-t37-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
- s65-t37-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
- s65-t37-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
- s65-t37-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
- s65-t37-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
- s65-t37-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
- s65-t37-sut1-c10/p1 - 100GE-port1 ConnectX6-2p100GE.
- s65-t37-sut1-c10/p2 - 100GE-port2 ConnectX6-2p100GE.
- SUT2 [Server-Type-F3]:
- testbedname: testbed37.
- hostname: s66-t37-sut2.
- IPMI IP: 10.30.50.76
- Host IP: 10.30.51.76
- portnames:
- s66-t37-sut2-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- s66-t37-sut2-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- s66-t37-sut2-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
- s66-t37-sut2-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
- s66-t37-sut2-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
- s66-t37-sut2-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
- s66-t37-sut2-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
- s66-t37-sut2-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
- s65-t37-sut1-c10/p1 - 100GE-port1 ConnectX6-2p100GE.
- s65-t37-sut1-c10/p2 - 100GE-port2 ConnectX6-2p100GE.
- TG [Server-Type-F3]:
- testbedname: testbed37.
- hostname: s67-t37-tg1.
- IPMI IP: 10.30.50.77
- Host IP: 10.30.51.77
- portnames:
- s67-t37-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- s67-t37-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- s67-t37-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
- s67-t37-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
- s67-t37-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
- s67-t37-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
- s67-t37-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
- s67-t37-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
- s67-t37-tg1-c10/p1 - 100GE-port1 ConnectX6-2p100GE.
- s67-t37-tg1-c10/p2 - 100GE-port2 ConnectX6-2p100GE.
- SUT1 [Server-Type-F3]:
- testbedname: testbed38.
- hostname: s78-t38-sut1.
- IPMI IP: 10.30.50.78
- Host IP: 10.30.51.78
- portnames:
- s78-t38-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- s78-t38-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- s78-t38-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
- s78-t38-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
- s78-t38-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
- s78-t38-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
- s78-t38-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
- s78-t38-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
- s78-t38-sut1-c10/p1 - 100GE-port1 ConnectX6-2p100GE.
- s78-t38-sut1-c10/p2 - 100GE-port2 ConnectX6-2p100GE.
- SUT2 [Server-Type-F3]:
- testbedname: testbed38.
- hostname: s79-t38-sut2.
- IPMI IP: 10.30.50.79
- Host IP: 10.30.51.79
- portnames:
- s79-t38-sut2-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- s79-t38-sut2-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- s79-t38-sut2-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
- s79-t38-sut2-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
- s79-t38-sut2-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
- s79-t38-sut2-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
- s79-t38-sut2-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
- s79-t38-sut2-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
- s79-t38-sut2-c10/p1 - 100GE-port1 ConnectX6-2p100GE.
- s79-t38-sut2-c10/p2 - 100GE-port2 ConnectX6-2p100GE.
- TG [Server-Type-F3]:
- testbedname: testbed38.
- hostname: s80-t38-tg1.
- IPMI IP: 10.30.50.80
- Host IP: 10.30.51.80
- portnames:
- s80-t38-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- s80-t38-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- s80-t38-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
- s80-t38-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
- s80-t38-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
- s80-t38-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
- s80-t38-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
- s80-t38-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
- s80-t38-tg1-c10/p1 - 100GE-port1 ConnectX6-2p100GE.
- s80-t38-tg1-c10/p2 - 100GE-port2 ConnectX6-2p100GE.
3-Node-SnowRidge (3n-snr) #
- ServerG1 [Server-Type-G1]:
- testbedname: testbed39.
- hostname: s93-t39-sut1.
- IPMI IP: 10.30.50.93
- Host IP: 10.30.51.93
- portnames:
- s93-t39-sut1-c1/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
- s93-t39-sut1-c1/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
- s93-t39-sut1-c1/p2 - 25GE-port3 e810-XXVDA4-4p25GE.
- s93-t39-sut1-c1/p2 - 25GE-port4 e810-XXVDA4-4p25GE.
- ServerG1 [Server-Type-G1]:
- testbedname: testbed39.
- hostname: s94-t39-sut2.
- IPMI IP: 10.30.50.94
- Host IP: 10.30.51.94
- portnames:
- s94-t39-sut2-c1/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
- s94-t39-sut2-c1/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
- s94-t39-sut2-c1/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
- s94-t39-sut2-c1/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
- ServerF4 [Server-Type-F5]:
- testbedname: testbed39.
- hostname: s89-t39t310-tg1.
- IPMI IP: 10.30.50.89
- Host IP: 10.30.51.89
- portnames:
- s89-t39t310-tg1-c6/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
- s89-t39t310-tg1-c6/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
- s89-t39t310-tg1-c6/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
- s89-t39t310-tg1-c6/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
2-Node-SapphireRapids (2n-spr) #
- SUT [Server-Type-H1]:
- testbedname: testbed21.
- hostname: s52-t21-sut1.
- IPMI IP: 10.30.50.52
- Host IP: 10.30.51.52
- portnames:
- s52-t21-sut1-c10/p1 - 200GE-port1 ConnectX7-2p200GE.
- s52-t21-sut1-c10/p2 - 200GE-port2 ConnectX7-2p200GE.
- s52-t21-sut1-c4/p1 - 200GE-port1 ConnectX7-2p200GE.
- s52-t21-sut1-c4/p2 - 200GE-port2 ConnectX7-2p200GE.
- s52-t21-sut1-c2/p1 - 200GE-port1 ConnectX7-2p200GE.
- s52-t21-sut1-c2/p2 - 200GE-port2 ConnectX7-2p200GE.
- s52-t21-sut1-c9/p1 - 200GE-port1 ConnectX7-2p200GE.
- s52-t21-sut1-c9/p2 - 200GE-port2 ConnectX7-2p200GE.
- s52-t21-sut1-c7/p1 - 200GE-port1 ConnectX7-2p200GE.
- s52-t21-sut1-c7/p2 - 200GE-port2 ConnectX7-2p200GE.
- TG [Server-Type-H2]:
- testbedname: testbed21.
- hostname: s53-t21-tg1.
- IPMI IP: 10.30.50.53
- Host IP: 10.30.51.53
- portnames:
- s53-t21-tg1-c10/p1 - 200GE-port1 ConnectX7-2p200GE.
- s53-t21-tg1-c10/p2 - 200GE-port2 ConnectX7-2p200GE.
- s53-t21-tg1-c4/p1 - 200GE-port1 ConnectX7-2p200GE.
- s53-t21-tg1-c4/p2 - 200GE-port2 ConnectX7-2p200GE.
- s53-t21-tg1-c2/p1 - 200GE-port1 ConnectX7-2p200GE.
- s53-t21-tg1-c2/p2 - 200GE-port2 ConnectX7-2p200GE.
- s53-t21-tg1-c9/p1 - 200GE-port1 ConnectX7-2p200GE.
- s53-t21-tg1-c9/p2 - 200GE-port2 ConnectX7-2p200GE.
- s53-t21-tg1-c7/p1 - 200GE-port1 ConnectX7-2p200GE.
- s53-t21-tg1-c7/p2 - 200GE-port2 ConnectX7-2p200GE.
- SUT [Server-Type-H3]:
- testbedname: testbed22.
- hostname: s54-t22-sut1.
- IPMI IP: 10.30.50.54
- Host IP: 10.30.51.54
- portnames:
- s54-t22-sut1-c2/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
- s54-t22-sut1-c2/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
- s54-t22-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
- s54-t22-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
- s54-t22-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
- s54-t22-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
- s54-t22-sut1-c7/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
- s54-t22-sut1-c7/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
- s54-t22-sut1-c9/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
- s54-t22-sut1-c9/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
- s54-t22-sut1-c9/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
- s54-t22-sut1-c9/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
- TG [Server-Type-H4]:
- testbedname: testbed22.
- hostname: s55-t22-tg1.
- IPMI IP: 10.30.50.55
- Host IP: 10.30.51.55
- portnames:
- s55-t22-tg1-c2/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
- s55-t22-tg1-c2/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
- s55-t22-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
- s55-t22-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
- s55-t22-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
- s55-t22-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
- SUT [Server-Type-H5]:
- testbedname: testbed23.
- hostname: s56-t23-sut1.
- IPMI IP: 10.30.50.56
- Host IP: 10.30.51.56
- portnames:
- s56-t23-sut1-c2/p1 - 200GE-port1 ConnectX7-2p200GE.
- s56-t23-sut1-c2/p2 - 200GE-port2 ConnectX7-2p200GE.
- s56-t23-sut1-c4/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
- s56-t23-sut1-c4/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
- s56-t23-sut1-c10/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
- s56-t23-sut1-c10/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
- s56-t23-sut1-c10/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
- s56-t23-sut1-c10/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
- TG [Server-Type-H6]:
- testbedname: testbed23.
- hostname: s57-t23-tg1.
- IPMI IP: 10.30.50.57
- Host IP: 10.30.51.57
- portnames:
- s57-t23-tg1-c2/p1 - 200GE-port1 ConnectX7-2p200GE.
- s57-t23-tg1-c2/p2 - 200GE-port2 ConnectX7-2p200GE.
- s57-t23-tg1-c4/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
- s57-t23-tg1-c4/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
- s57-t23-tg1-c10/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
- s57-t23-tg1-c10/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
- s57-t23-tg1-c10/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
- s57-t23-tg1-c10/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
- s57-t23-tg1-c7/p1 - 200GE-port1 ConnectX7-2p200GE.
- s57-t23-tg1-c7/p2 - 200GE-port2 ConnectX7-2p200GE.
- s57-t23-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
- s57-t23-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
- SUT [Server-Type-H5]:
- testbedname: testbed24.
- hostname: s58-t24-sut1.
- IPMI IP: 10.30.50.58
- Host IP: 10.30.51.58
- portnames:
- s58-t24-sut1-c2/p1 - 200GE-port1 ConnectX7-2p200GE.
- s58-t24-sut1-c2/p2 - 200GE-port2 ConnectX7-2p200GE.
- s58-t24-sut1-c4/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
- s58-t24-sut1-c4/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
- s58-t24-sut1-c10/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
- s58-t24-sut1-c10/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
- s58-t24-sut1-c10/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
- s58-t24-sut1-c10/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
- TG [Server-Type-H6]:
- testbedname: testbed24.
- hostname: s59-t24-tg1.
- IPMI IP: 10.30.50.59
- Host IP: 10.30.51.59
- portnames:
- s59-t24-tg1-c2/p1 - 200GE-port1 ConnectX7-2p200GE.
- s59-t24-tg1-c2/p2 - 200GE-port2 ConnectX7-2p200GE.
- s59-t24-tg1-c4/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
- s59-t24-tg1-c4/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
- s59-t24-tg1-c10/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
- s59-t24-tg1-c10/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
- s59-t24-tg1-c10/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
- s59-t24-tg1-c10/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
- s59-t24-tg1-c7/p1 - 200GE-port1 ConnectX7-2p200GE.
- s59-t24-tg1-c7/p2 - 200GE-port2 ConnectX7-2p200GE.
- s59-t24-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
- s59-t24-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
3-Node-IcelakeD (3n-icxd) #
- ServerI1 [Server-Type-I1]:
- testbedname: testbed31.
- hostname: s32-t31-sut1.
- IPMI IP: 10.30.50.32
- Host IP: 10.30.51.32
- portnames:
- s32-t31-sut1-c1/p1 - 25GE-port1 e822cq-2p25GE.
- s32-t31-sut1-c1/p2 - 25GE-port2 e822cq-2p25GE.
- ServerI1 [Server-Type-I1]:
- testbedname: testbed31.
- hostname: s33-t31-sut2.
- IPMI IP: 10.30.50.33
- Host IP: 10.30.51.33
- portnames:
- s33-t31-sut2-c1/p1 - 25GE-port1 e822cq-2p25GE.
- s33-t31-sut2-c1/p2 - 25GE-port2 e822cq-2p25GE.
- ServerF3 [Server-Type-F5]:
- testbedname: testbed31.
- hostname: s90-t31t32-tg1.
- IPMI IP: 10.30.50.90
- Host IP: 10.30.51.90
- portnames:
- s90-t31t32-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
- s90-t31t32-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
- s90-t31t32-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
- s90-t31t32-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
- ServerI1 [Server-Type-I1]:
- testbedname: testbed32.
- hostname: s34-t32-sut1.
- IPMI IP: 10.30.50.34
- Host IP: 10.30.51.34
- portnames:
- s34-t32-sut1-c1/p1 - 25GE-port1 e822cq-2p25GE.
- s34-t32-sut1-c1/p2 - 25GE-port2 e822cq-2p25GE.
- ServerI1 [Server-Type-I1]:
- testbedname: testbed32.
- hostname: s35-t32-sut2.
- IPMI IP: 10.30.50.35
- Host IP: 10.30.51.35
- portnames:
- s35-t32-sut2-c1/p1 - 25GE-port1 e822cq-2p25GE.
- s35-t32-sut2-c1/p2 - 25GE-port2 e822cq-2p25GE.
- ServerF3 [Server-Type-F5]:
- testbedname: testbed32.
- hostname: s90-t31t32-tg1.
- IPMI IP: 10.30.50.90
- Host IP: 10.30.51.90
- portnames:
- s90-t31t32-tg1-c6/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
- s90-t31t32-tg1-c6/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
- s90-t31t32-tg1-c6/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
- s90-t31t32-tg1-c6/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
Testbed Wiring #
1-Node-Skylake (1n-skx) #
- testbed11:
- ring1 10GE-ports x710-4p10GE:
- s1-t11-sut1-c2/p1 to s1-t11-sut1-c4/p1.
- ring2 10GE-ports x710-4p10GE:
- s1-t11-sut1-c2/p2 to s1-t11-sut1-c4/p2.
- ring3 10GE-ports x710-4p10GE:
- s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
- ring4 10GE-ports x710-4p10GE:
- s1-t11-sut1-c2/p4 to s1-t11-sut1-c4/p4.
- ring5 100GE-ports e810-2p100GE:
- s1-t11-sut1-c5/p1 to s1-t11-sut1-c6/p1.
- ring6 100GE-ports e810-2p100GE:
- s1-t11-sut1-c5/p2 to s1-t11-sut1-c6/p2.
- testbed12:
- ring1 10GE-ports x710-4p10GE:
- s2-t12-sut1-c2/p1 to s2-t12-sut1-c4/p1.
- ring2 10GE-ports x710-4p10GE:
- s2-t12-sut1-c2/p2 to s2-t12-sut1-c4/p2.
- ring3 10GE-ports x710-4p10GE:
- s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
- ring4 10GE-ports x710-4p10GE:
- s2-t12-sut1-c2/p4 to s2-t12-sut1-c4/p4.
- ring5 100GE-ports e810-2p100GE:
- s2-t12-sut1-c5/p1 to s2-t12-sut1-c6/p1.
- ring6 100GE-ports e810-2p100GE:
- s2-t12-sut1-c5/p2 to s2-t12-sut1-c6/p2.
1-Node-Altra (1n-alt) #
- testbed13:
- ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
- s70-t13-sut1-c0/p1 - s70-t13-sut1-c3/p1.
- ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
- s70-t13-sut1-c0/p2 - s70-t13-sut1-c3/p2.
- ring3 100GE-ports ConnectX6-2p100GE on SUTs:
- s70-t13-sut1-c1/p1 - s70-t13-sut1-c1/p2.
- ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
- s70-t13-sut1-c2/p1 - s70-t13-sut1-c5/p1.
- ring5 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
- s70-t13-sut1-c2/p2 - s70-t13-sut1-c5/p2.
- testbed14:
- ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
- s71-t14-sut1-c0/p1 - s71-t14-sut1-c3/p1.
- ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
- s71-t14-sut1-c0/p2 - s71-t14-sut1-c3/p2.
- ring3 100GE-ports ConnectX6-2p100GE on SUTs:
- s71-t14-sut1-c1/p1 - s71-t14-sut1-c1/p2.
- ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
- s71-t14-sut1-c2/p1 - s71-t14-sut1-c5/p1.
- ring5 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
- s71-t14-sut1-c2/p2 - s71-t14-sut1-c5/p2.
1-Node-SapphireRapids (1n-spr) #
- testbed15:
- ring1 100GE-ports e810-2p100GE:
- s30-t15-sut1-c1/p1 to s30-t15-sut1-c2/p1.
- ring2 100GE-ports e810-2p100GE:
- s30-t15-sut1-c1/p2 to s30-t15-sut1-c2/p2.
- testbed16:
- ring1 100GE-ports e810-2p100GE:
- s31-t16-sut1-c1/p1 to s31-t16-sut1-c2/p1.
- ring2 100GE-ports e810-2p100GE:
- s31-t16-sut1-c1/p2 to s31-t16-sut1-c2/p2.
2-Node-IxiaPS1L47 (2n-ps1) #
- testbed25:
- link1 10GE-port x710-4p10GE on SUT:
- t25-tg1-p1 to t25-sut1-c2/p1.
- link2 10GE-port x710-4p10GE on SUT:
- t25-tg1-p2 to t25-sut1-c2/p2.
- link3 10GE-port x710-4p10GE on SUT:
- t25-tg1-p3 to t25-sut1-c2/p3.
- link4 10GE-port x710-4p10GE on SUT:
- t25-tg1-p4 to t25-sut1-c2/p4.
2-Node-Cascadelake (2n-clx) #
- testbed27:
- ring1 10GE-ports x710-4p10GE on SUT:
- s34-t27-tg1-c2/p1 to s33-t27-sut1-c2/p1.
- s33-t27-sut1-c2/p2 to s34-t27-tg1-c2/p2.
- ring2 10GE-ports x710-4p10GE on SUT:
- s34-t27-tg1-c2/p3 to s33-t27-sut1-c2/p3.
- s33-t27-sut1-c2/p4 to s34-t27-tg1-c2/p4.
- ring3 25GE-ports xxv710-DA2-2p25GE on SUT
- s34-t27-tg1-c4/p1 to s33-t27-sut1-c4/p1.
- s33-t27-sut1-c4/p2 to s34-t27-tg1-c4/p2.
- ring4 100GE-ports ConnectX5-2p100GE on SUT:
- s34-t27-tg1-c9/p1 to s33-t27-sut1-c9/p1.
- s33-t27-sut1-c9/p2 to s34-t27-tg1-c9/p2.
- ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG:
- s34-t27-tg1-c6/p1 to s33-t27-sut1-c6/p1.
- s33-t27-sut1-c6/p2 to s34-t27-tg1-c6/p2.
- ring6 100GE-ports e810-2p100GE on TG:
- s34-t27-tg1-c8/p1 to s34-t27-tg1-c8/p2.
- s34-t27-tg1-c8/p2 to s34-t27-tg1-c8/p1.
- testbed28:
- ring1 10GE-ports x710-4p10GE on SUT:
- s36-t28-tg1-c2/p1 to s35-t28-sut1-c2/p1.
- s35-t28-sut1-c2/p2 to s36-t28-tg1-c2/p2.
- ring2 10GE-ports x710-4p10GE on SUT:
- s36-t28-tg1-c2/p3 to s35-t28-sut1-c2/p3.
- s35-t28-sut1-c2/p4 to s36-t28-tg1-c2/p4.
- ring3 25GE-ports xxv710-DA2-2p25GE on SUT
- s36-t28-tg1-c4/p1 to s35-t28-sut1-c4/p1.
- s35-t28-sut1-c4/p2 to s36-t28-tg1-c4/p2.
- ring4 100GE-ports ConnectX5-2p100GE on SUT:
- s36-t28-tg1-c9/p1 to s35-t28-sut1-c9/p1.
- s35-t28-sut1-c9/p2 to s36-t28-tg1-c9/p2.
- ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG:
- s36-t28-tg1-c6/p1 to s35-t28-sut1-c6/p1.
- s35-t28-sut1-c6/p2 to s36-t28-tg1-c6/p2.
- ring6 100GE-ports e810-2p100GE on TG:
- s36-t28-tg1-c8/p1 to s36-t28-tg1-c8/p2.
- s36-t28-tg1-c8/p2 to s36-t28-tg1-c8/p1.
- testbed29:
- ring1 10GE-ports x710-4p10GE on SUT:
- s38-t29-tg1-c2/p1 to s37-t29-sut1-c2/p1.
- s37-t29-sut1-c2/p2 to s38-t29-tg1-c2/p2.
- ring2 10GE-ports x710-4p10GE on SUT:
- s38-t29-tg1-c2/p3 to s37-t29-sut1-c2/p3.
- s37-t29-sut1-c2/p4 to s38-t29-tg1-c2/p4.
- ring3 25GE-ports xxv710-DA2-2p25GE on SUT
- s38-t29-tg1-c4/p1 to s37-t29-sut1-c4/p1.
- s37-t29-sut1-c4/p2 to s38-t29-tg1-c4/p2.
- ring4 100GE-ports ConnectX5-2p100GE on SUT:
- s38-t29-tg1-c9/p1 to s37-t29-sut1-c9/p1.
- s37-t29-sut1-c9/p2 to s38-t29-tg1-c9/p2.
- ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG:
- s38-t29-tg1-c6/p1 to s37-t29-sut1-c6/p1.
- s37-t29-sut1-c6/p2 to s38-t29-tg1-c6/p2.
2-Node-Zen2 (2n-zn2) #
- testbed210:
- ring1 10GE-ports x710-4p10GE on SUT:
- s61-t210-tg1-c2/p1 to s60-t210-sut1-c1/p1.
- s60-t210-sut1-c1/p2 to s61-t210-tg1-c2/p2.
- ring2 10GE-ports x710-4p10GE on SUT:
- s61-t210-tg1-c2/p3 to s60-t210-sut1-c1/p3.
- s60-t210-sut1-c1/p4 to s61-t210-tg1-c2/p4.
- ring3 25GE-ports xxv710-DA2-2p25GE on SUT
- s61-t210-tg1-c3/p1 to s60-t210-sut1-c2/p1.
- s60-t210-sut1-c2/p2 to s61-t210-tg1-c3/p2.
- ring4 100GE-ports ConnectX5-2p100GE on SUT:
- s61-t210-tg1-c1/p1 to s60-t210-sut1-c3/p1.
- s60-t210-sut1-c3/p2 to s61-t210-tg1-c1/p2.
2-Node-ThunderX2 (2n-tx2) #
- testbed211:
- ring1 10GE-ports x520-2p10GE on SUTs:
- s27-t211-sut1-c18/p1 - s19-t33t211-tg1-c8/p1.
- s27-t211-sut1-c18/p2 - s19-t33t211-tg1-c8/p2.
2-Node-Icelake (2n-icx) #
- testbed212:
- ring1 25GE-ports xxv710-DA2-2p25GE:
- s72-t212-tg1-c2/p1 to s71-t212-sut1-c2/p1.
- s71-t212-sut1-c2/p2 to s72-t212-tg1-c2/p2.
- ring2 25GE-ports e810-XXVDA4-2p25GE:
- s72-t212-tg1-c4/p1 to s71-t212-sut1-c4/p1.
- s71-t212-sut1-c4/p2 to s72-t212-tg1-c4/p2.
- s72-t212-tg1-c4/p3 to s71-t212-sut1-c4/p3.
- s71-t212-sut1-c4/p4 to s72-t212-tg1-c4/p4.
- ring3 100GE-ports e810-2CQDA2-2p100GE:
- s72-t212-tg1-c9/p1 to s71-t212-sut1-c9/p1.
- s71-t212-sut1-c9/p2 to s72-t212-tg1-c9/p2.
- ring4 100GE-ports e810-2CQDA2-2p100GE:
- s72-t212-tg1-c6/p1 to s72-t212-tg1-c6/p2.
- s72-t212-tg1-c6/p2 to s72-t212-tg1-c6/p1.
- ring5 200GE-ports ConnectX7-2p200GE:
- s72-t212-tg1-c8/p1 to s71-t212-sut1-c8/p1.
- s71-t212-sut1-c8/p2 to s72-t212-tg1-c8/p2.
- testbed213:
- ring1 25GE-ports xxv710-DA2-2p25GE:
- s84-t213-tg1-c2/p1 to s83-t213-sut1-c2/p1.
- s83-t213-sut1-c2/p2 to s84-t213-tg1-c2/p2.
- ring2 25GE-ports e810-XXVDA4-2p25GE:
- s84-t213-tg1-c4/p1 to s83-t213-sut1-c4/p1.
- s83-t213-sut1-c4/p2 to s84-t213-tg1-c4/p2.
- s84-t213-tg1-c4/p3 to s83-t213-sut1-c4/p3.
- s83-t213-sut1-c4/p4 to s84-t213-tg1-c4/p4.
- ring3 100GE-ports e810-2CQDA2-2p100GE:
- s84-t213-tg1-c9/p1 to s83-t213-sut1-c9/p1.
- s83-t213-sut1-c9/p2 to s84-t213-tg1-c9/p2.
- ring4 100GE-ports e810-2CQDA2-2p100GE:
- s84-t213-tg1-c6/p1 to s84-t213-tg1-c6/p2.
- s84-t213-tg1-c6/p2 to s84-t213-tg1-c6/p1.
- ring5 200GE-ports ConnectX7-2p200GE:
- s84-t213-tg1-c8/p1 to s83-t213-sut1-c8/p1.
- s83-t213-sut1-c8/p2 to s84-t213-tg1-c8/p2.
- testbed214:
- ring1 25GE-ports xxv710-DA2-2p25GE:
- s86-t214-tg1-c2/p1 to s85-t214-sut1-c2/p1.
- s85-t214-sut1-c2/p2 to s86-t214-tg1-c2/p2.
- ring2 25GE-ports e810-XXVDA4-2p25GE:
- s86-t214-tg1-c4/p1 to s85-t214-sut1-c4/p1.
- s85-t214-sut1-c4/p2 to s86-t214-tg1-c4/p2.
- s86-t214-tg1-c4/p3 to s85-t214-sut1-c4/p3.
- s85-t214-sut1-c4/p4 to s86-t214-tg1-c4/p4.
- ring3 100GE-ports e810-2CQDA2-2p100GE:
- s86-t214-tg1-c9/p1 to s85-t214-sut1-c9/p1.
- s85-t214-sut1-c9/p2 to s86-t214-tg1-c9/p2.
- ring4 100GE-ports e810-2CQDA2-2p100GE:
- s86-t214-tg1-c6/p1 to s86-t214-tg1-c6/p2.
- s86-t214-tg1-c6/p2 to s86-t214-tg1-c6/p1.
- ring5 200GE-ports ConnectX7-2p200GE:
- s86-t214-tg1-c8/p1 to s85-t214-sut1-c8/p1.
- s85-t214-sut1-c8/p2 to s86-t214-tg1-c8/p2.
- testbed215:
- ring1 25GE-ports xxv710-DA2-2p25GE:
- s88-t215-tg1-c2/p1 to s87-t215-sut1-c2/p1.
- s87-t215-sut1-c2/p2 to s88-t215-tg1-c2/p2.
- ring2 25GE-ports e810-XXVDA4-2p25GE:
- s88-t215-tg1-c4/p1 to s87-t215-sut1-c4/p1.
- s87-t215-sut1-c4/p2 to s88-t215-tg1-c4/p2.
- s88-t215-tg1-c4/p3 to s87-t215-sut1-c4/p3.
- s87-t215-sut1-c4/p4 to s88-t215-tg1-c4/p4.
- ring3 100GE-ports e810-2CQDA2-2p100GE:
- s88-t215-tg1-c9/p1 to s87-t215-sut1-c9/p1.
- s87-t215-sut1-c9/p2 to s88-t215-tg1-c9/p2.
- ring4 100GE-ports e810-2CQDA2-2p100GE:
- s88-t215-tg1-c6/p1 to s88-t215-tg1-c6/p2.
- s88-t215-tg1-c6/p2 to s88-t215-tg1-c6/p1.
- ring5 200GE-ports ConnectX7-2p200GE:
- s88-t215-tg1-c8/p1 to s87-t215-sut1-c8/p1.
- s87-t215-sut1-c8/p2 to s88-t215-tg1-c8/p2.
3-Node-Rangeley (3n-rng) #
To be completed.
3-Node-Taishan (3n-tsh) #
- testbed33:
- ring1 10GE-ports x520-2p10GE on SUTs:
- s19-t33t211-tg1-c2/p2 - s17-t33-sut1-c6/p2.
- s17-t33-sut1-c6/p1 - s18-t33-sut2-c6/p2.
- s18-t33-sut2-c6/p1 - s19-t33t211-tg1-c2/p1.
- ring2 25GE-ports cx4-2p25GE on SUTs:
- s19-t33t211-tg1-c4/p2 - s17-t33-sut1-c4/p2.
- s17-t33-sut1-c4/p1 - s18-t33-sut2-c4/p2.
- s18-t33-sut2-c4/p1 - s19-t33t211-tg1-c4/p1.
3-Node-Altra (3n-alt) #
- testbed34:
- ring1 40GE-ports xl710-QDA2-2p40GE on SUTs:
- s64-t34-tg1-c4/p1 - s62-t34-sut1-c1/p2.
- s62-t34-sut1-c1/p1 - s63-t34-sut2-c1/p2.
- s63-t34-sut2-c1/p1 - s64-t34-tg1-c4/p2.
- ring2 100GE-ports ConnectX6-2p100GE Mellanox on SUTs:
- s64-t34-tg1-c8/p1 - s62-t34-sut2-c8/p1.
- s62-t34-sut1-c8/p1 - s63-t34-sut2-c8/p2.
- s63-t34-sut1-c8/p2 - s64-t34-tg1-c8/p2.
3-Node-Icelake (3n-icx) #
- testbed37:
- ring1 25GE-ports xxv710-DA2-2p25GE:
- s67-t37-tg1-c2/p1 to s65-t37-sut1-c2/p1.
- s65-t37-sut1-c2/p2 to s66-t37-sut2-c2/p2.
- s66-t37-sut2-c2/p1 to s67-t37-tg1-c2/p2.
- ring2 25GE-ports e810-XXVDA4-4p25GE:
- s67-t37-tg1-c4/p1 to s65-t37-sut1-c4/p1.
- s65-t37-sut1-c4/p2 to s66-t37-sut2-c4/p2.
- s66-t37-sut2-c4/p1 to s67-t37-tg1-c4/p2.
- s67-t37-tg1-c4/p3 to s65-t37-sut1-c4/p3.
- s65-t37-sut1-c4/p4 to s66-t37-sut2-c4/p4.
- s66-t37-sut2-c4/p3 to s67-t37-tg1-c4/p4.
- ring3 100GE-ports e810-2CQDA2-2p100GE:
- s67-t37-tg1-c9/p1 to s65-t37-sut1-c9/p1.
- s65-t37-sut1-c9/p2 to s66-t37-sut2-c9/p2.
- s66-t37-sut2-c9/p1 to s67-t37-tg1-c9/p2.
- ring4 200GE-ports ConnectX6-2p200GE:
- s67-t37-tg1-c10/p1 - s65-t37-sut1-c10/p2.
- s65-t37-sut1-c10/p1 - s66-t37-sut2-c10/p2.
- s66-t37-sut2-c10/p1 - s67-t37-tg1-c10/p2.
- testbed38:
- ring1 25GE-ports xxv710-DA2-2p25GE:
- s80-t38-tg1-c2/p1 to s78-t38-sut1-c2/p1.
- s78-t38-sut1-c2/p2 to s79-t38-sut2-c2/p2.
- s79-t38-sut2-c2/p1 to s80-t38-tg1-c2/p2.
- ring2 25GE-ports e810-XXVDA4-4p25GE:
- s80-t38-tg1-c4/p1 to s78-t38-sut1-c4/p1.
- s78-t38-sut1-c4/p2 to s79-t38-sut2-c4/p2.
- s79-t38-sut2-c4/p1 to s80-t38-tg1-c4/p2.
- s80-t38-tg1-c4/p3 to s78-t38-sut1-c4/p3.
- s78-t38-sut1-c4/p4 to s79-t38-sut2-c4/p4.
- s79-t38-sut2-c4/p3 to s80-t38-tg1-c4/p4.
- ring3 100GE-ports e810-2CQDA2-2p100GE:
- s80-t38-tg1-c9/p1 to s78-t38-sut1-c9/p1.
- s78-t38-sut1-c9/p2 to s79-t38-sut2-c9/p2.
- s79-t38-sut2-c9/p1 to s80-t38-tg1-c9/p2.
- ring4 200GE-ports ConnectX6-2p200GE:
- s80-t38-tg1-c10/p1 to s78-t38-sut1-c10/p1.
- s78-t38-sut1-c10/p2 to s79-t38-sut2-c10/p2.
- s79-t38-sut2-c10/p1 to s80-t38-tg1-c10/p2.
3-Node-SnowRidge (3n-snr) #
- testbed39:
- ring1 25GE-ports e810-XXVDA4-4p25GE:
- s89-t39t310-tg1-c6/p1 to s93-t39-sut1-c1/p1.
- s93-t39-sut1-c1/p2 to s94-t39-sut2-c1/p2.
- s94-t39-sut2-c1/p1 to s89-t39t310-tg1-c6/p2.
- s89-t39t310-tg1-c6/p3 to s93-t39-sut1-c1/p3.
- s93-t39-sut1-c1/p4 to s94-t39-sut2-c1/p4.
- s94-t39-sut2-c1/p3 to s89-t39t310-tg1-c6/p4.
2-Node-SapphireRapids (2n-spr) #
- testbed21:
- ring1 200GE-ports ConnectX7-2p200GE:
- s53-t21-tg1-c2/p1 to s52-t21-sut1-c2/p1
- s53-t21-tg1-c7/p1 to s52-t21-sut1-c7/p1
- s52-t21-sut1-c4/p2 to s52-t21-sut1-c9/p2
- ring2 200GE-ports ConnectX7-2p200GE:
- s53-t21-tg1-c2/p2 to s52-t21-sut1-c2/p2
- s53-t21-tg1-c7/p2 to s52-t21-sut1-c7/p2
- s52-t21-sut1-c10/p1 to s52-t21-sut1-c11/p1
- ring3 200GE-ports ConnectX7-2p200GE:
- s53-t21-tg1-c4/p1 to s52-t21-sut1-c4/p1
- s53-t21-tg1-c9/p1 to s52-t21-sut1-c9/p1
- s52-t21-sut1-c10/p2 to s52-t21-sut1-c11/p2
- testbed22:
- ring1 100GE-ports e810-2CQDA2-2p100GE:
- s55-t22-tg1-c4/p1 to s54-t22-sut1-c9/p2
- s55-t22-tg1-c4/p2 to s54-t22-sut1-c4/p2
- s54-t22-sut1-c9/p1 to s54-t22-sut1-c4/p1
- ring2 25GE-ports e810-XXVDA4-4p25GE:
- s55-t22-tg1-c2/p1 to s54-t22-sut1-c2/p1
- s55-t22-tg1-c2/p2 to s54-t22-sut1-c7/p1
- s54-t22-sut1-c2/p2 to s54-t22-sut1-c7/p2
- testbed23:
- ring1 200GE-ports ConnectX7-2p200GE:
- s56-t23-sut1-c2/p1 to s57-t23-tg1-c2/p1.
- s57-t23-tg1-c2/p2 to s56-t23-sut1-c2/p2.
- ring2 100GE-ports e810-2CQDA2-2p100GE:
- s56-t23-sut1-c4/p1 to s57-t23-tg1-c4/p1.
- s57-t23-tg1-c4/p2 to s56-t23-sut1-c4/p2.
- ring3 25GE-ports e810-XXVDA4-4p25GE:
- s56-t23-sut1-c10/p1 to s57-t23-tg1-c10/p1.
- s56-t23-sut1-c10/p2 to s57-t23-tg1-c10/p2.
- s56-t23-sut1-c10/p3 to s57-t23-tg1-c10/p3.
- s56-t23-sut1-c10/p4 to s57-t23-tg1-c10/p4.
- ring4 200GE-ports ConnectX7-2p200GE:
- s57-t23-tg1-c7/p1 to s57-t23-tg1-c7/p2.
- ring5 100GE-ports e810-2CQDA2-2p100GE:
- s57-t23-tg1-c9/p1 to s57-t23-tg1-c9/p2.
- testbed24:
- ring1 200GE-ports ConnectX7-2p200GE:
- s58-t24-sut1-c2/p1 to s59-t24-tg1-c2/p1.
- s59-t24-tg1-c2/p2 to s58-t24-sut1-c2/p2.
- ring2 100GE-ports e810-2CQDA2-2p100GE:
- s58-t24-sut1-c4/p1 to s59-t24-tg1-c4/p1.
- s59-t24-tg1-c4/p2 to s58-t24-sut1-c4/p2.
- ring3 25GE-ports e810-XXVDA4-4p25GE:
- s58-t24-sut1-c10/p1 to s59-t24-tg1-c10/p1.
- s58-t24-sut1-c10/p2 to s59-t24-tg1-c10/p2.
- s58-t24-sut1-c10/p3 to s59-t24-tg1-c10/p3.
- s58-t24-sut1-c10/p4 to s59-t24-tg1-c10/p4.
- ring4 200GE-ports ConnectX7-2p200GE:
- s59-t24-tg1-c7/p1 to s59-t24-tg1-c7/p2.
- ring5 100GE-ports e810-2CQDA2-2p100GE:
- s59-t24-tg1-c9/p1 to s59-t24-tg1-c9/p2.
3-Node-IcelakeD (3n-icxd) #
- testbed31:
- ring1 25GE-ports e822cq-2p25GE:
- s90-t31t32-tg1-c4/p1 to s32-t31-sut1-c1/p1.
- s32-t31-sut1-c1/p2 to s33-t31-sut2-c1/p2.
- s33-t31-sut2-c1/p1 to s90-t31t32-tg1-c4/p2.
- testbed32:
- ring1 25GE-ports e822cq-2p25GE:
- s90-t31t32-tg1-c6/p1 to s34-t32-sut1-c1/p1.
- s34-t32-sut1-c1/p2 to s35-t32-sut2-c1/p2.
- s35-t32-sut2-c1/p1 to s90-t31t32-tg1-c6/p2.