FD.io DC Testbed Specifications

FD.io DC Testbed Specifications #

Purpose #

This note includes specification of the physical testbed infrastructure hosted by LFN FD.io CSIT project.

Server Management #

Addressing #

Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a Management port, which are connected to two different VLANs.

LOM (IPMI) VLAN #

  • Subnet: 10.30.50.0/24
  • Gateway: 10.30.50.1
  • Broadcast: 10.30.50.255
  • DNS1: 199.204.44.24
  • DNS2: 199.204.47.54

Management VLAN #

  • Subnet: 10.30.51.0/24
  • Gateway: 10.30.51.1
  • Broadcast: 10.30.51.255
  • DNS1: 199.204.44.24
  • DNS2: 199.204.47.54

To access these hosts, VPN connection is required.

Testbeds Overview #

Summary List #

 #. Type                 Purpose  SUT   TG    #TB  #SUT #TG  #skx #ps1 #rng #tx2 #tsh #alt #clx #zn2 #icx #snr #spr #icxd #grc
 1. 1-Node-Skylake         nomad  skx   na    2    2    0    2    0    0    0    0    0    0    0    0    0    0    0     0
 2. 1-Node-Cascadelake     nomad  clx   na    4    4    0    0    0    0    0    0    0    4    0    0    0    0    0     0
 3. 1-Node-AmpereAltra     nomad  alt   na    4    4    0    0    0    0    0    0    4    0    0    0    0    0    0     0
 4. 1-Node-SapphireRapids  nomad  spr   na    4    4    0    0    0    0    0    0    0    0    0    0    0    4    0     0
 6. 2-Node-Icelake         perf   icx   icx   3    3    3    0    0    0    0    0    0    0    0    6    0    0    0     0
 7. 2-Node-Octeon          perf   icx   icx   1    1    1    0    0    0    0    0    0    0    0    2    0    0    0     0
 8. 2-Node-Zen2            perf   zn2   zn2   1    1    1    0    0    0    0    0    0    0    2    0    0    0    0     0
 9. 3-Node-Altra           perf   alt   icx   1    2    1    0    0    0    0    0    2    0    0    1    0    0    0     0
10. 3-Node-Icelake         perf   icx   icx   2    4    2    0    0    0    0    0    0    0    0    6    0    0    0     0
11. 3-Node-SnowRidge       perf   snr   icx   1    2    .5   0    0    0    0    0    0    .5   0    0    2    0    0     0
12. 2-Node-SapphireRapids  perf   spr   spr   4    4    4    0    0    0    0    0    0    0    0    0    0    8    0     0
13. 3-Node-IcelakeD        perf   icxd  icx   2    4    1    0    0    0    0    0    0    0    0    1    0    0    4     0
14. 2-Node-Grace           perf   grc   icx   1    1    1    0    0    0    0    0    0    0    0    1    0    0    0     1

2-Node-Zen2 EPYC AMD (2n-zn2) #

Each 2-Node-Zen2 testbed includes one SUT (Server-Type-D1) and one TG (Server-Type-D2) connected in a 2-node circular topology (Server Types). Used for FD.io performance tests.

2-Node-Icelake Xeon Intel (2n-icx) #

Each 2-Node-Icelake testbed includes one SUT (Server-Type-F1) and one TG (Server-Type-F2) connected in a 2-node circular topology (Server Types). Used for FD.io performance tests.

2-Node-Icelake Xeon Intel (2n-oct) #

Each 2-Node-Icelake testbed includes one SUT (Server-Type-XX) and one TG (Server-Type-XX) connected in a 2-node circular topology (Server Types). Used for FD.io performance tests.

2-Node-Grace Server Nvidia (2n-grc) #

Each 2-Node-Grace testbed includes one SUT (Server-Type-XX) and one TG (Server-Type-F6) connected in a 2-node circular topology (Server Types). Used for FD.io performance tests.

3-Node-Altra Arm Ampere (3n-alt) #

Each 3-Node-Altra testbed includes two SUTs (Server-Type-E23) and one TG (Server-Type-E32) connected in a 3-node circular topology (Server Types). Used for FD.io performance tests.

3-Node-Icelake Xeon Intel (3n-icx) #

Each 3-Node-Icelake testbed includes two SUTs (Server-Type-F3) and one TG (Server-Type-F3) connected in a 3-node circular topology (Server Types). Used for FD.io performance tests.

3-Node-IcelakeD Xeon Intel (3n-icxd) #

Each 3-Node-IcelakeD testbed includes two SUTs (Server-Type-I1) and one numa of TG (Server-Type-F5) connected in a 3-node circular topology (Server Types). Used for FD.io performance tests.

3-Node-SnowRidge Atom Intel (3n-snr) #

Each 3-Node-SnowRidge testbed includes two SUTs (Server-Type-G1) and one TG (Server-Type-F5) connected in a 3-node circular topology (Server Types). Used for FD.io performance tests.

2-Node-SapphireRapids Xeon Intel (2n-spr) #

Each 2-Node-SapphireRapids testbed includes one SUT (Server-Type-H5) and one TG (Server-Type-H6) connected in a 2-node or 3-node circular topology (Server Types). Used for FD.io performance tests.

Testbed Naming Convention #

Following naming convention is used within this page to specify physical connectivity and wiring across defined CSIT testbeds:

  • testbedname: testbedN.
  • hostname:
    • traffic-generator: tN-tgW.
    • system-under-testX: tN-sutX.
  • portnames:
    • tN-tgW-cY/pZ.
    • tN-sutX-cY/pZ.
  • where:
    • N - testbed number.
    • tgW - server acts as traffic-generator with W index.
    • sutX - server acts as system-under-test with X index.
    • Y - PCIe slot number denoting a NIC card number within the host.
    • Z - port number on the NIC card.

Server Types #

FD.io CSIT lab contains following server types:

  1. Server-Type-B1: Purpose - Skylake Xeon hosts for FD.io builds and data processing (BUILDER).

    • Quantity: 2
    • Physical connectivity:
      • IPMI and host management ports.
    • Main HW configuration:
      • Chassis: SuperMicro SYS-7049GP-TRT.
      • Motherboard: SuperMicro X11DPG-QT.
      • Processors: 2* Intel Platinum 8180 2.5 GHz.
      • RAM Memory: 16* 16GB DDR4-2666MHz.
      • Disks: 2* 1.6TB 6G SATA SSD.
    • NICs configuration:
      • Numa0: (x16, x16, x16 PCIe3.0 lanes)
        • PCIe Slot2 18:00.xx: empty.
        • PCIe Slot4 3b:00.xx: empty.
        • PCIe Slot9 5e:00.xx: empty.
      • Numa1: (x16, x16, x16 PCIe3.0 lanes)
        • PCIe Slot6 86:00.xx: empty.
        • PCIe Slot8 af:00.xx: empty.
        • PCIe Slot10 d8:00.xx: empty.
  2. Server-Type-B2: Purpose - Skylake Xeon hosts for FD.io builds and data processing (HST).

    • Quantity: 2
    • Physical connectivity:
      • IPMI and host management ports.
    • Main HW configuration:
      • Chassis: SuperMicro SYS-7049GP-TRT.
      • Motherboard: SuperMicro X11DPG-QT.
      • Processors: 2* Intel Platinum 8180 2.5 GHz.
      • RAM Memory: 16* 16GB DDR4-2666MHz.
      • Disks: 2* 1.6TB 6G SATA SSD.
    • NICs configuration:
      • Numa0: (x16, x16, x16 PCIe3.0 lanes)
        • PCIe Slot2 18:00.xx: e810-2p100GE Intel.
        • PCIe Slot4 3b:00.xx: e810-2p100GE Intel.
        • PCIe Slot9 5e:00.xx: empty.
      • Numa1: (x16, x16, x16 PCIe3.0 lanes)
        • PCIe Slot6 86:00.xx: empty.
        • PCIe Slot8 af:00.xx: empty.
        • PCIe Slot10 d8:00.xx: empty.
  3. Server-Type-C2: Purpose - Cascadelake Xeon Shared TG for FD.io performance testing.

    • Quantity: 1.
    • Physical connectivity:
      • IPMI and host management ports.
      • NIC ports connected into 3-node testbed topologies.
    • Main HW configuration:
      • Chassis: SuperMicro SYS-7049GP-TRT.
      • Motherboard: SuperMicro X11DPG-QT.
      • Processors: 2* Intel Platinum 8280 2.7 GHz.
      • RAM Memory: 12* 16GB DDR4-2933.
      • Disks: 2* 1.92TB SATA SSD.
    • NICs configuration:
      • Numa0: (x16, x16, x16 PCIe4.0 lanes)
        • PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
        • PCIe Slot4 31:00.xx: empty.
        • PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel.
      • Numa1: (x16, x16, x16 PCIe4.0 lanes)
        • PCIe Slot6 86:00.xx: e810-XXVDA4-4p25GE Intel.
        • PCIe Slot8 af:00.xx: empty.
        • PCIe Slot10 d8:00.xx: empty.
  4. Server-Type-C3: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing.

    • Quantity: 4.
    • Physical connectivity:
      • IPMI and host management ports.
      • no NIC ports, standalone setup.
    • Main HW configuration:
      • Chassis: SuperMicro 1029P-WTRT.
      • Motherboard: SuperMicro X11DDW-NT.
      • Processors: 2* Intel Platinum 8280 2.7 GHz.
      • RAM Memory: 12* 16GB DDR4-2933.
      • Disks: 4* 1.92TB SATA SSD.
    • NICs configuration:
      • Numa0: (x16, x16, x16 PCIe3.0 lanes)
        • PCIe Slot2 18:00.xx: empty.
        • PCIe Slot4 3b:00.xx: empty.
        • PCIe Slot9 5e:00.xx: empty.
      • Numa1: (x16, x16, x16 PCIe3.0 lanes)
        • PCIe Slot6 86:00.xx: empty.
        • PCIe Slot8 af:00.xx: empty.
        • PCIe Slot10 d8:00.xx: empty.
  5. Server-Type-D1: Purpose - Zen2 EPYC SUT for FD.io performance testing.

    • Quantity: 1.
    • Physical connectivity:
      • IPMI and host management ports.
      • NIC ports connected into 2-node testbed topologies.
    • Main HW configuration:
      • Chassis: SuperMicro AS-1114S-WTRT
      • Processors: 1* AMD EPYC 7532 2.4 GHz.
      • RAM Memory: 8* 32GB DDR4-2933.
      • Disks: 1* 1TB SATA SSD.
    • NICs configuration:
      • Numa0: (x16, x16, x16 PCIe3.0 lanes)
        • PCIe Slot1 01:00.xx: x710-4p10GE Intel.
        • PCIe Slot2 41:00.xx: xxv710-da2-2p25GE Intel.
        • PCIe Slot3 81:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
  6. Server-Type-D2: Purpose - Zen2 EPYC TG for FD.io performance testing.

    • Quantity: 1.
    • Physical connectivity:
      • IPMI and host management ports.
      • NIC ports connected into 2-node testbed topologies.
    • Main HW configuration:
      • Chassis: SuperMicro AS-1114S-WTRT
      • Processors: 1* AMD EPYC 7532 2.4 GHz.
      • RAM Memory: 8* 32GB DDR4-2933.
      • Disks: 1* 1TB SATA SSD.
    • NICs configuration:
      • Numa0: (x16, x16, x16 PCIe3.0 lanes)
        • PCIe Slot1 01:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
        • PCIe Slot2 41:00.xx: x710-4p10GE Intel.
        • PCIe Slot3 81:00.xx: xxv710-da2 2p25GE Intel.
  7. Server-Type-E23: Purpose - Altra Arm Ampere SUT for FD.io performance testing.

    • Quantity: 2.
    • Physical connectivity:
      • IPMI and host management ports.
      • NIC ports connected into 3-node topologies.
    • Main HW configuration:
      • Chassis: WIWYNN Mt.Jade Server System B81.030Z1.0007 2U
      • Motherboard: Mt.Jade Motherboard
      • Processors: 2* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1)
      • Processor Signature: Implementor 0x41, Variant 0x3, Architecture 15, Part 0xd0c, Revision 1
      • RAM Memory: 16* 8GB DDR4-3200MT/s
      • Disks: 2* 960GB SSD Samsung M.2 NVMe PM983
    • NICs configuration:
      • Numa0: (x16, x16 PCIe4.0 lanes)
        • PCIe Slot1 0004:04:00.x: xl710-QDA2-2p40GE Intel.
        • PCIe Slot8 0001:00:00.x: ConnectX6-2p100GE Mellanox.
      • Numa1:
        • no cards.
  8. Server-Type-E24: Purpose - Altra Arm Ampere for FD.io build.

    • Quantity: 2.
    • Physical connectivity:
      • IPMI and host management ports.
    • Main HW configuration:
      • Chassis: Gigabyte R152-P30-00 1U
      • Motherboard: MP32-AR1-00
      • Processors: 1* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1)
      • Processor Signature: Implementor 0x0a, Variant 0x1, Architecture 6, Part 0x000, Revision 1
      • RAM Memory: 12* 16GB DDR4-3200MT/s
      • Disks: 1* 960GB SSD Samsung M.2 NVMe PM983
  9. Server-Type-E25: Purpose - Altra Arm Ampere for FD.io build.

    • Quantity: 2.
    • Physical connectivity:
      • IPMI and host management ports.
      • NIC ports connected into 1-node topologies.
    • Main HW configuration:
      • Chassis: Gigabyte E252-P30-00 2U
      • Motherboard: MP32-AR1-00
      • Processors: 1* Ampere(R) Altra(R) M128-30 Processor (Neoverse N1)
      • Processor Signature: Implementor 0x41 (Arm), Variant 0x3, Architecture 0xf, Part 0xd0c (neoverse-n1), Revision 0x1
      • RAM Memory: 32* 32GB DDR4-3200MT/s
      • Disks: 2* 960GB SSD Samsung M.2 NVMe PM9A3
    • NICs configuration:
      • Numa0:
        • PCIe Slot0 0000:01:00.xx: XL710-QDA2-2p40GE Intel.
        • PCIe Slot1 0001:01:00.xx: ConnectX6-2p100GE Mellanox.
        • PCIe Slot2 0002:03:00.xx: ConnectX5-2p10/25GE Mellanox.
      • Numa1:
        • PCIe Slot3 0003:02:00.xx: XL710-QDA2-2p40GE Intel.
        • PCIe Slot5 0005:02:00.xx: ConnectX5-2p10/25GE Mellanox.
  10. Server-Type-E32: Purpose - Icelake Xeon Shared TG for FD.io performance testing.

    • Quantity: 1.
    • Physical connectivity:
      • IPMI and host management ports.
      • NIC ports connected into 2-node and/or 3-node testbed topologies.
    • Main HW configuration:
      • Chassis: SuperMicro SYS-740GP-TNRT.
      • Motherboard: Super X12DPG-QT6.
      • Processors: 2* Intel Platinum 8358 2.6 GHz.
      • RAM Memory: 16* 16GB DDR4-3200.
      • Disks: 2* 960GB SATA SSD.
    • NICs configuration:
      • Numa0: (x16, x16, x16 PCIe4.0 lanes)
        • PCIe Slot2 4b:00.xx: xxv710-DA2-2p25GE Intel.
        • PCIe Slot4 31:00.xx: xl710-QDA2-2p40GE Intel.
        • PCIe Slot9 ff:00.xx: empty.
      • Numa1: (x16, x16, x16 PCIe4.0 lanes)
        • PCIe Slot6 ca:00.xx: empty.
        • PCIe Slot8 b1:00.xx: e810-2CQDA2-2p100GE Intel.
        • PCIe Slot10 ff:00.xx: empty.
  11. Server-Type-F1: Purpose - Icelake Xeon SUT for FD.io performance testing.

    • Quantity: 4.
    • Physical connectivity:
      • IPMI and host management ports.
      • NIC ports connected into 2-node topology.
    • Main HW configuration:
      • Chassis: SuperMicro SYS-740GP-TNRT.
      • Motherboard: Super X12DPG-QT6.
      • Processors: 2* Intel Platinum 8358 2.6 GHz.
      • RAM Memory: 16* 16GB DDR4-3200.
      • Disks: 2* 960GB SATA SSD.
    • NICs configuration:
      • Numa0: (x16, x16, x16 PCIe4.0 lanes)
        • PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
        • PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
        • PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel.
      • Numa1: (x16, x16, x16 PCIe4.0 lanes)
        • PCIe Slot6 86:00.xx: empty.
        • PCIe Slot8 af:00.xx: ConnectX7-2p200GE Mellanox.
        • PCIe Slot10 d8:00.xx: empty.
  12. Server-Type-F2: Purpose - Icelake Xeon TG for FD.io performance testing.

    • Quantity: 4.
    • Physical connectivity:
      • IPMI and host management ports.
      • NIC ports connected into 2-node testbed topologies.
    • Main HW configuration:
      • Chassis: SuperMicro SYS-740GP-TNRT.
      • Motherboard: Super X12DPG-QT6.
      • Processors: 2* Intel Platinum 8358 2.6 GHz.
      • RAM Memory: 16* 16GB DDR4-3200.
      • Disks: 2* 960GB SATA SSD.
    • NICs configuration:
      • Numa0: (x16, x16, x16 PCIe4.0 lanes)
        • PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
        • PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
        • PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel.
      • Numa1: (x16, x16, x16 PCIe4.0 lanes)
        • PCIe Slot6 86:00.xx: e810-2CQDA2-2p100GE Intel.
        • PCIe Slot8 af:00.xx: ConnectX7-2p200GE Mellanox.
        • PCIe Slot10 d8:00.xx: empty.
  13. Server-Type-F3: Purpose - Icelake Xeon TG or SUT for FD.io performance testing.

    • Quantity: 6.
    • Physical connectivity:
      • IPMI and host management ports.
      • NIC ports connected into 3-node testbed topologies.
    • Main HW configuration:
      • Chassis: SuperMicro SYS-740GP-TNRT.
      • Motherboard: Super X12DPG-QT6.
      • Processors: 2* Intel Platinum 8358 2.6 GHz.
      • RAM Memory: 16* 16GB DDR4-3200.
      • Disks: 2* 960GB SATA SSD.
    • NICs configuration:
      • Numa0: (x16, x16, x16 PCIe4.0 lanes)
        • PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
        • PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
        • PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel.
      • Numa1: (x16, x16, x16 PCIe4.0 lanes)
        • PCIe Slot6 86:00.xx: ConnectX6-2p100GE Mellanox.
        • PCIe Slot8 af:00.xx: empty.
        • PCIe Slot10 d8:00.xx: empty.
  14. Server-Type-F4: Purpose - Icelake Xeon TG for FD.io performance testing.

    • Quantity: 3.
    • Physical connectivity:
      • IPMI and host management ports.
      • NIC ports connected into 3-node testbed topologies.
    • Main HW configuration:
      • Chassis: SuperMicro SYS-740GP-TNRT.
      • Motherboard: Super X12DPG-QT6.
      • Processors: 2* Intel Platinum 8358 2.6 GHz.
      • RAM Memory: 16* 16GB DDR4-3200.
      • Disks: 2* 960GB SATA SSD.
    • NICs configuration:
      • Numa0: (x16, x16, x16 PCIe4.0 lanes)
        • PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
        • PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
        • PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel.
      • Numa1: (x16, x16, x16 PCIe4.0 lanes)
        • PCIe Slot6 86:00.xx: ConnectX6-2p100GE Mellanox.
        • PCIe Slot8 af:00.xx: empty.
        • PCIe Slot10 d8:00.xx: empty.
  15. Server-Type-F5: Purpose - Icelake Xeon Shared TG for FD.io performance testing.

    • Quantity: 2.
    • Physical connectivity:
      • IPMI and host management ports.
      • NIC ports connected into 2-node and/or 3-node testbed topologies.
    • Main HW configuration:
      • Chassis: SuperMicro SYS-740GP-TNRT.
      • Motherboard: Super X12DPG-QT6.
      • Processors: 2* Intel Platinum 8358 2.6 GHz.
      • RAM Memory: 16* 16GB DDR4-3200.
      • Disks: 2* 960GB SATA SSD.
    • NICs configuration:
      • Numa0: (x16, x16, x16 PCIe4.0 lanes)
        • PCIe Slot2 4b:00.xx: xxv710-DA2-2p25GE Intel.
        • PCIe Slot4 31:00.xx: empty.
        • PCIe Slot9 ff:00.xx: empty.
      • Numa1: (x16, x16, x16 PCIe4.0 lanes)
        • PCIe Slot6 ca:00.xx: e810-XXVDA4-4p25GE Intel.
        • PCIe Slot8 b1:00.xx: e810-2CQDA2-2p100GE Intel.
        • PCIe Slot10 ff:00.xx: empty.
  16. Server-Type-F6: Purpose - Icelake Xeon TG for FD.io performance testing.

    • Quantity: 1.
    • Physical connectivity:
      • IPMI and host management ports.
      • NIC ports connected into 2-node and/or 3-node testbed topologies.
    • Main HW configuration:
      • Chassis: SuperMicro SYS-740GP-TNRT.
      • Motherboard: Super X12DPG-QT6.
      • Processors: 2* Intel Platinum 8358 2.6 GHz.
      • RAM Memory: 16* 16GB DDR4-3200.
      • Disks: 2* 960GB SATA SSD.
    • NICs configuration:
      • Numa0: (x16, x16, x16 PCIe4.0 lanes)
        • PCIe Slot2 4b:00.xx: ConnectX5-2p100GE Mellanox.
        • PCIe Slot4 31:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
        • PCIe Slot9 ff:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
      • Numa1: (x16, x16, x16 PCIe4.0 lanes)
        • PCIe Slot6 ca:00.xx: empty.
        • PCIe Slot8 b1:00.xx: empty.
        • PCIe Slot10 ff:00.xx: empty.
  17. Server-Type-G1: Purpose - SnowRidge Atom SUT for FD.io performance testing.

    • Quantity: 2
    • Physical connectivity:
      • IPMI and host management ports.
      • NIC ports connected into 3-node testbed topology.
    • Main HW configuration:
      • Chassis: Intel JACOBSVILLE SDP.
      • Motherboard: Intel JACOBSVILLE E63448-400.
      • Processors: 1* Intel Atom P5362B 2.2 GHz.
      • RAM Memory: 2* 16GB DDR4-2933.
      • Disks: ?* ? SATA SSD.
    • NICs configuration:
      • Numa0: (x16, PCIe3.0 lane)
        • PCIe BuiltIn ec:00.xx: e810-XXVDA4-4p25GE Intel.
  18. Server-Type-H1: Purpose - SapphireRapids Xeon SUT for FD.io full system performance testing.

    • Quantity: 1.
    • Physical connectivity:
      • IPMI and host management ports.
      • NIC ports connected into 3-numa-node testbed topologies.
    • Main HW configuration:
      • Chassis: SuperMicro SYS-741GE-TNRT.
      • Motherboard: Super X13DEG-QT-P.
      • Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP.
      • RAM Memory: 16* 32GB DDR5-4800.
      • Disks: 2* 960GB SATA SSD.
    • NICs configuration:
      • Numa0: (x16, x16, x16 PCIe5.0 lanes)
        • PCIe Slot2 18:00.xx: ConnectX7-2p200GE Nvidia.
        • PCIe Slot4 3b:00.xx: ConnectX7-2p200GE Nvidia.
        • PCIe Slot10 5e:00.xx: ConnectX7-2p200GE Nvidia.
      • Numa1: (x16, x16, x16 PCIe5.0 lanes)
        • PCIe Slot7 86:00.xx: ConnectX7-2p200GE Nvidia.
        • PCIe Slot9 af:00.xx: ConnectX7-2p200GE Nvidia.
        • PCIe Slot11 d8:00.xx: ConnectX7-2p200GE Nvidia.
  19. Server-Type-H2: Purpose - SapphireRapids Xeon TG for FD.io full system performance testing.

    • Quantity: 1.
    • Physical connectivity:
      • IPMI and host management ports.
      • NIC ports connected into 3-numa-node testbed topologies.
    • Main HW configuration:
      • Chassis: SuperMicro SYS-741GE-TNRT.
      • Motherboard: Super X13DEG-QT-P.
      • Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP.
      • RAM Memory: 16* 32GB DDR5-4800.
      • Disks: 2* 960GB SATA SSD.
    • NICs configuration:
      • Numa0: (x16, x16, x16 PCIe5.0 lanes)
        • PCIe Slot2 18:00.xx: ConnectX7-2p200GE Nvidia.
        • PCIe Slot4 3b:00.xx: ConnectX7-2p200GE Nvidia.
        • PCIe Slot10 5e:00.xx: ConnectX7-2p200GE Nvidia.
      • Numa1: (x16, x16, x16 PCIe5.0 lanes)
        • PCIe Slot7 86:00.xx: ConnectX7-2p200GE Nvidia.
        • PCIe Slot9 af:00.xx: ConnectX7-2p200GE Nvidia.
        • PCIe Slot11 d8:00.xx: empty.
  20. Server-Type-H3: Purpose - SapphireRapids Xeon SUT for FD.io performance testing.

    • Quantity: 1.
    • Physical connectivity:
      • IPMI and host management ports.
      • NIC ports connected into 3-numa-node testbed topologies.
    • Main HW configuration:
      • Chassis: SuperMicro SYS-741GE-TNRT.
      • Motherboard: Super X13DEG-QT-P.
      • Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP.
      • RAM Memory: 16* 32GB DDR5-4800.
      • Disks: 2* 960GB SATA SSD.
    • NICs configuration:
      • Numa0: (x16, x16, x16 PCIe5.0 lanes)
        • PCIe Slot2 18:00.xx: e810-2CQDA2-2p100GE Intel.
        • PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
        • PCIe Slot10 5e:00.xx: empty.
      • Numa1: (x16, x16, x16 PCIe5.0 lanes)
        • PCIe Slot7 86:00.xx: e810-2CQDA2-2p100GE Intel.
        • PCIe Slot9 af:00.xx: e810-XXVDA4-4p25GE Intel.
        • PCIe Slot11 d8:00.xx: empty.
  21. Server-Type-H4: Purpose - SapphireRapids Xeon TG for FD.io performance testing.

    • Quantity: 1.
    • Physical connectivity:
      • IPMI and host management ports.
      • NIC ports connected into 3-numa-node testbed topologies.
    • Main HW configuration:
      • Chassis: SuperMicro SYS-741GE-TNRT.
      • Motherboard: Super X13DEG-QT-P.
      • Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP.
      • RAM Memory: 16* 32GB DDR5-4800.
      • Disks: 2* 960GB SATA SSD.
    • NICs configuration:
      • Numa0: (x16, x16, x16 PCIe5.0 lanes)
        • PCIe Slot2 18:00.xx: e810-2CQDA2-2p100GE Intel.
        • PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
        • PCIe Slot10 5e:00.xx: empty.
      • Numa1: (x16, x16, x16 PCIe5.0 lanes)
        • PCIe Slot7 86:00.xx: empty.
        • PCIe Slot9 af:00.xx: empty.
        • PCIe Slot11 d8:00.xx: empty.
  22. Server-Type-H5: Purpose - SapphireRapids Xeon SUT for FD.io performance testing.

    • Quantity: 2.
    • Physical connectivity:
      • IPMI and host management ports.
      • NIC ports connected into 2-node testbed topologies.
    • Main HW configuration:
      • Chassis: SuperMicro SYS-741GE-TNRT.
      • Motherboard: Super X13DEG-QT-P.
      • Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP.
      • RAM Memory: 16* 32GB DDR5-4800.
      • Disks: 2* 960GB SATA SSD.
    • NICs configuration:
      • Numa0: (x16, x16, x16 PCIe5.0 lanes)
        • PCIe Slot2 3d:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
        • PCIe Slot4 2c:00.xx: e810-2CQDA2-2p100GE Intel.
        • PCIe Slot10 17:00.xx: e810-XXVDA4-4p25GE Intel.
      • Numa1: (x16, x16, x16 PCIe5.0 lanes)
        • PCIe Slot7 86:00.xx: empty.
        • PCIe Slot9 af:00.xx: empty.
        • PCIe Slot11 d8:00.xx: empty.
  23. Server-Type-H6: Purpose - SapphireRapids Xeon TG for FD.io performance testing.

    • Quantity: 2.
    • Physical connectivity:
      • IPMI and host management ports.
      • NIC ports connected into 2-node testbed topologies plus loopbacks in Numa1 for TG self-test.
    • Main HW configuration:
      • Chassis: SuperMicro SYS-741GE-TNRT.
      • Motherboard: Super X13DEG-QT-P.
      • Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP.
      • RAM Memory: 16* 32GB DDR5-4800.
      • Disks: 2* 960GB SATA SSD.
    • NICs configuration:
      • Numa0: (x16, x16, x16 PCIe5.0 lanes)
        • PCIe Slot2 18:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
        • PCIe Slot4 3b:00.xx: e810-2CQDA2-2p100GE Intel.
        • PCIe Slot10 5e:00.xx: e810-XXVDA4-4p25GE Intel.
      • Numa1: (x16, x16, x16 PCIe5.0 lanes)
        • PCIe Slot7 86:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
        • PCIe Slot9 af:00.xx: e810-2CQDA2-2p100GE Intel.
        • PCIe Slot11 d8:00.xx: empty.
  24. Server-Type-H7: Purpose - SapphireRapids SUT for FD.io build.

    • Quantity: 2.
    • Physical connectivity:
      • IPMI and host management ports.
      • NIC ports connected into 1-node topologies.
    • Main HW configuration:
      • Chassis: SuperMicro SYS-741GE-TNRT.
      • Motherboard: Super X13DEG-QT-P.
      • Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP.
      • RAM Memory: 16* 32GB DDR5-4800.
      • Disks: 2* 960GB SATA SSD.
    • NICs configuration:
      • Numa0: (x16, x16, x16 PCIe5.0 lanes)
        • PCIe Slot2 18:00.xx: e810-2CQDA2-2p100GE Intel.
        • PCIe Slot4 3b:00.xx: e810-2CQDA2-2p100GE Intel.
        • PCIe Slot10 5e:00.xx: empty.
      • Numa1: (x16, x16, x16 PCIe5.0 lanes)
        • PCIe Slot7 86:00.xx: empty.
        • PCIe Slot9 af:00.xx: empty.
        • PCIe Slot11 d8:00.xx: empty.
  25. Server-Type-I1: Purpose - IcelakeD Xeon SUT for FD.io performance testing.

    • Quantity: 4
    • Physical connectivity:
      • IPMI and host management ports.
      • NIC ports connected into 3-node testbed topology.
    • Main HW configuration:
      • Chassis: SuperMicro SYS-110D-20C-FRDN8TP.
      • Motherboard: Super X12SDV-20C-SPT8F.
      • Processors: 1* Intel Xeon D-2796NT.
      • RAM Memory: 4* 32GB DDR4-3200 MEM-DR432MD-ER32.
      • Disks: 1* 960GB SATA SSD HDS-25T0.
    • NICs configuration:
      • Numa0: (x16, PCIe4.0 lane)
        • PCIe BuiltIn ??:00.xx: e810-XXVDA2-2p25GE Intel.
  26. Server-Type-J1: Purpose - Grace Server SUT for FD.io performance testing.

    • Quantity: 1.
    • Physical connectivity:
      • IPMI and host management ports.
      • NIC ports connected into 2-node and/or 3-node testbed topologies.
    • Main HW configuration:
      • Chassis: NDA.
      • Motherboard: NDA.
      • Processors: 1* Arm Neoverse V2.
      • RAM Memory: NDA.
      • Disks: NDA.
    • NICs configuration:
      • Numa0: (x16, x16, x16, x16 PCIe5.0 lanes)
        • PCIe Slot2 ?: ConnectX5-2p100GE Mellanox.
        • PCIe Slot4 ?: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
        • PCIe Slot9 ?: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.

Testbeds Configuration #

1-Node-Skylake (1n-skx) #

- SUT [Server-Type-B2]:
    - testbedname: testbed11.
    - hostname: s50-nomad.
    - IPMI IP: 10.30.50.47
    - Host IP: 10.30.51.50
    - portnames:
        - s1-t11-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
        - s1-t11-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
        - s1-t11-sut1-c8/p1 - 100GE-port1 e810-2p100GE.
        - s1-t11-sut1-c8/p2 - 100GE-port2 e810-2p100GE.
- SUT [Server-Type-B2]:
    - testbedname: testbed12.
    - hostname: s51-nomad.
    - IPMI IP: 10.30.50.48
    - Host IP: 10.30.51.51
    - portnames:
        - s2-t12-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
        - s2-t12-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
        - s2-t12-sut1-c8/p1 - 100GE-port1 e810-2p100GE.
        - s2-t12-sut1-c8/p2 - 100GE-port2 e810-2p100GE.

1-Node-Altra (1n-alt) #

- SUT [Server-Type-E25]:
    - testbedname: testbed13
    - hostname: s70-nomad
    - IPMI IP: 10.30.50.70
    - Host IP: 10.30.51.70
    - portnames:
        - s70-t13-sut1-c0/p1 - 40GE-port1 XL710-QDA2-2p40GE.
        - s70-t13-sut1-c0/p2 - 40GE-port2 XL710-QDA2-2p40GE.
        - s70-t13-sut1-c1/p1 - 100GE-port1 ConnectX6-2p100GE Mellanox.
        - s70-t13-sut1-c1/p2 - 100GE-port2 ConnectX6-2p100GE Mellanox.
        - s70-t13-sut1-c2/p1 - 25GE-port1 ConnectX5-2p10/25GE Mellanox.
        - s70-t13-sut1-c2/p2 - 25GE-port2 ConnectX5-2p10/25GE Mellanox.
        - s70-t13-sut1-c3/p1 - 40GE-port1 XL710-QDA2-2p40GE.
        - s70-t13-sut1-c3/p2 - 40GE-port2 XL710-QDA2-2p40GE.
        - s70-t13-sut1-c5/p1 - 25GE-port1 ConnectX5-2p10/25GE Mellanox.
        - s70-t13-sut1-c5/p2 - 25GE-port2 ConnectX5-2p10/25GE Mellanox.
- SUT [Server-Type-E25]:
    - testbedname: testbed14
    - hostname: s71-nomad
    - IPMI IP: 10.30.50.71
    - Host IP: 10.30.51.71
    - portnames:
        - s71-t14-sut1-c0/p1 - 40GE-port1 XL710-QDA2-2p40GE.
        - s71-t14-sut1-c0/p2 - 40GE-port2 XL710-QDA2-2p40GE.
        - s71-t14-sut1-c1/p1 - 100GE-port1 ConnectX6-2p100GE Mellanox.
        - s71-t14-sut1-c1/p2 - 100GE-port2 ConnectX6-2p100GE Mellanox.
        - s71-t14-sut1-c2/p1 - 25GE-port1 ConnectX5-2p10/25GE Mellanox.
        - s71-t14-sut1-c2/p2 - 25GE-port2 ConnectX5-2p10/25GE Mellanox.
        - s71-t14-sut1-c3/p1 - 40GE-port1 XL710-QDA2-2p40GE.
        - s71-t14-sut1-c3/p2 - 40GE-port2 XL710-QDA2-2p40GE.
        - s71-t14-sut1-c5/p1 - 25GE-port1 ConnectX5-2p10/25GE Mellanox.
        - s71-t14-sut1-c5/p2 - 25GE-port2 ConnectX5-2p10/25GE Mellanox.

1-Node-SapphireRapids (1n-spr) #

- SUT [Server-Type-H7]:
    - testbedname: testbed15.
    - hostname: s30-nomad.
    - IPMI IP: 10.30.50.30
    - Host IP: 10.30.51.30
    - portnames:
        - s30-t15-sut1-c1/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
        - s30-t15-sut1-c1/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
        - s30-t15-sut1-c2/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
        - s30-t15-sut1-c2/p2 - 100GE-port1 e810-2CQDA2-2p100GE.
        - s30-t15-sut1-c7/p1 - 10GE-port1 x710-4p10GE.
        - s30-t15-sut1-c7/p2 - 10GE-port2 x710-4p10GE.
        - s30-t15-sut1-c7/p3 - 10GE-port3 x710-4p10GE.
        - s30-t15-sut1-c7/p4 - 10GE-port4 x710-4p10GE.
        - s30-t15-sut1-c9/p1 - 10GE-port1 x710-4p10GE.
        - s30-t15-sut1-c9/p2 - 10GE-port2 x710-4p10GE.
        - s30-t15-sut1-c9/p3 - 10GE-port3 x710-4p10GE.
        - s30-t15-sut1-c9/p4 - 10GE-port4 x710-4p10GE.
- SUT [Server-Type-H7]:
    - testbedname: testbed16.
    - hostname: s31-nomad.
    - IPMI IP: 10.30.50.31
    - Host IP: 10.30.51.31
    - portnames:
        - s31-t16-sut1-c1/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
        - s31-t16-sut1-c1/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
        - s31-t16-sut1-c2/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
        - s31-t16-sut1-c2/p2 - 100GE-port1 e810-2CQDA2-2p100GE.
        - s31-t16-sut1-c7/p1 - 10GE-port1 x710-4p10GE.
        - s31-t16-sut1-c7/p2 - 10GE-port2 x710-4p10GE.
        - s31-t16-sut1-c7/p3 - 10GE-port3 x710-4p10GE.
        - s31-t16-sut1-c7/p4 - 10GE-port4 x710-4p10GE.
        - s31-t16-sut1-c9/p1 - 10GE-port1 x710-4p10GE.
        - s31-t16-sut1-c9/p2 - 10GE-port2 x710-4p10GE.
        - s31-t16-sut1-c9/p3 - 10GE-port3 x710-4p10GE.
        - s31-t16-sut1-c9/p4 - 10GE-port4 x710-4p10GE.

2-Node-Cascadelake (2n-clx) #

- TG [Server-Type-C2]:
    - testbedname: testbed29.
    - hostname: s38-t29-tg1.
    - IPMI IP: 10.30.55.23
    - Host IP: 10.32.8.23
    - portnames:
        - s38-t29-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
        - s38-t29-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
        - s38-t29-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
        - s38-t29-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
        - s38-t29-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
        - s38-t29-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
        - s38-t29-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE.
        - s38-t29-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE.
        - s38-t29-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
        - s38-t29-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.

2-Node-Zen2 (2n-zn2) #

- SUT [Server-Type-D1]:
    - testbedname: testbed210.
    - hostname: s60-t210-sut1.
    - IPMI IP: 10.30.55.24
    - Host IP: 10.32.8.24
    - portnames:
        - s60-t210-sut1-c1/p1 - 10GE-port1 x710-4p10GE.
        - s60-t210-sut1-c1/p2 - 10GE-port2 x710-4p10GE.
        - s60-t210-sut1-c1/p3 - 10GE-port3 x710-4p10GE.
        - s60-t210-sut1-c1/p4 - 10GE-port4 x710-4p10GE.
        - s60-t210-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
        - s60-t210-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
        - s60-t210-sut1-c3/p1 - 100GE-port1 ConnectX5-2p100GE.
        - s60-t210-sut1-c3/p2 - 100GE-port2 ConnectX5-2p100GE.
- TG [Server-Type-D2]:
    - testbedname: testbed210.
    - hostname: s61-t210-tg1.
    - IPMI IP: 10.30.55.25
    - Host IP: 10.32.8.25
    - portnames:
        - s61-t210-tg1-c1/p1 - 100GE-port1 ConnectX5-2p100GE.
        - s61-t210-tg1-c1/p2 - 100GE-port2 ConnectX5-2p100GE.
        - s61-t210-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
        - s61-t210-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
        - s61-t210-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
        - s61-t210-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
        - s61-t210-tg1-c3/p1 - 25GE-port1 xxv710-DA2-2p25GE.
        - s61-t210-tg1-c3/p2 - 25GE-port2 xxv710-DA2-2p25GE.

2-Node-Icelake (2n-icx) #

- SUT [Server-Type-F1]:
    - testbedname: testbed212.
    - hostname: s71-t212-sut1.
    - IPMI IP: 10.30.50.81
    - Host IP: 10.30.51.81
    - portnames:
        - s71-t212-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
        - s71-t212-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
        - s71-t212-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
        - s71-t212-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
        - s71-t212-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
        - s71-t212-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
        - s71-t212-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
        - s71-t212-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
        - s71-t212-sut1-c8/p1 - 200GE-port1 ConnectX7-2p200GE.
        - s71-t212-sut1-c8/p2 - 200GE-port2 ConnectX7-2p200GE.
- TG [Server-Type-F2]:
    - testbedname: testbed212.
    - hostname: s72-t212-tg1.
    - IPMI IP: 10.30.50.82
    - Host IP: 10.30.51.82
    - portnames:
        - s72-t212-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
        - s72-t212-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
        - s72-t212-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
        - s72-t212-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
        - s72-t212-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
        - s72-t212-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
        - s72-t212-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
        - s72-t212-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
        - s72-t212-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
        - s72-t212-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
        - s72-t212-tg1-c8/p1 - 200GE-port1 ConnectX7-2p200GE.
        - s72-t212-tg1-c8/p2 - 200GE-port2 ConnectX7-2p200GE.
- SUT [Server-Type-F1]:
    - testbedname: testbed213.
    - hostname: s83-t213-sut1.
    - IPMI IP: 10.30.50.83
    - Host IP: 10.30.51.83
    - portnames:
        - s83-t213-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
        - s83-t213-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
        - s83-t213-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
        - s83-t213-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
        - s83-t213-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
        - s83-t213-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
        - s83-t213-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
        - s83-t213-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
        - s83-t213-sut1-c8/p1 - 200GE-port1 ConnectX7-2p200GE.
        - s83-t213-sut1-c8/p2 - 200GE-port2 ConnectX7-2p200GE.
- TG [Server-Type-F2]:
    - testbedname: testbed213.
    - hostname: s84-t213-tg1.
    - IPMI IP: 10.30.50.84
    - Host IP: 10.30.51.84
    - portnames:
        - s84-t213-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
        - s84-t213-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
        - s84-t213-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
        - s84-t213-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
        - s84-t213-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
        - s84-t213-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
        - s84-t213-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
        - s84-t213-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
        - s84-t213-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
        - s84-t213-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
        - s84-t213-tg1-c8/p1 - 200GE-port1 ConnectX7-2p200GE.
        - s84-t213-tg1-c8/p2 - 200GE-port2 ConnectX7-2p200GE.
- SUT [Server-Type-F1]:
    - testbedname: testbed214.
    - hostname: s85-t214-sut1.
    - IPMI IP: 10.30.50.85
    - Host IP: 10.30.51.85
    - portnames:
        - s85-t214-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
        - s85-t214-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
        - s85-t214-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
        - s85-t214-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
        - s85-t214-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
        - s85-t214-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
        - s85-t214-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
        - s85-t214-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
        - s85-t214-sut1-c8/p1 - 200GE-port1 ConnectX7-2p200GE.
        - s85-t214-sut1-c8/p2 - 200GE-port2 ConnectX7-2p200GE.
- TG [Server-Type-F2]:
    - testbedname: testbed214.
    - hostname: s86-t214-tg1.
    - IPMI IP: 10.30.50.86
    - Host IP: 10.30.51.86
    - portnames:
        - s86-t214-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
        - s86-t214-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
        - s86-t214-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
        - s86-t214-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
        - s86-t214-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
        - s86-t214-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
        - s86-t214-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
        - s86-t214-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
        - s86-t214-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
        - s86-t214-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
        - s86-t214-tg1-c8/p1 - 200GE-port1 ConnectX7-2p200GE.
        - s86-t214-tg1-c8/p2 - 200GE-port2 ConnectX7-2p200GE.

2-Node-Icelake (2n-oct) #

- SUT [Server-Type-F1]:
    - testbedname: testbed215.
    - hostname: s87-t215-sut1.
    - IPMI IP: 10.30.50.87
    - Host IP: 10.30.51.87
    - portnames:
        - s87-t215-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
        - s87-t215-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
        - s87-t215-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
        - s87-t215-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
        - s87-t215-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
        - s87-t215-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
        - s87-t215-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
        - s87-t215-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
        - s87-t215-sut1-c8/p1 - 200GE-port1 ConnectX7-2p200GE.
        - s87-t215-sut1-c8/p2 - 200GE-port2 ConnectX7-2p200GE.
- TG [Server-Type-F2]:
    - testbedname: testbed215.
    - hostname: s88-t215-tg1.
    - IPMI IP: 10.30.50.88
    - Host IP: 10.30.51.88
    - portnames:
        - s88-t215-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
        - s88-t215-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
        - s88-t215-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
        - s88-t215-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
        - s88-t215-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
        - s88-t215-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
        - s88-t215-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
        - s88-t215-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
        - s88-t215-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
        - s88-t215-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
        - s88-t215-tg1-c8/p1 - 200GE-port1 ConnectX7-2p200GE.
        - s88-t215-tg1-c8/p2 - 200GE-port2 ConnectX7-2p200GE.

3-Node-Altra (3n-alt) #

- SUT [Server-Type-E23]:
    - testbedname: testbed34.
    - hostname: s62-t34-sut1.
    - IPMI IP: 10.30.50.72
    - Host IP: 10.30.51.72
    - portnames:
        - s62-t34-sut1-c1/p1 - 40GE-port1 xl710-QDA2-2p40GE.
        - s62-t34-sut1-c1/p2 - 40GE-port2 xl710-QDA2-2p40GE.
        - s62-t34-sut1-c8/p1 - 100GE-port1 ConnectX6-2p100GE.
        - s62-t34-sut1-c8/p2 - 100GE-port2 ConnectX6-2p100GE.
- SUT [Server-Type-E23]:
    - testbedname: testbed34.
    - hostname: s63-t34-sut2.
    - IPMI IP: 10.30.50.73
    - Host IP: 10.30.51.73
    - portnames:
        - s63-t34-sut2-c1/p1 - 40GE-port1 xl710-QDA2-2p40GE.
        - s63-t34-sut2-c1/p2 - 40GE-port2 xl710-QDA2-2p40GE.
        - s63-t34-sut2-c8/p1 - 100GE-port1 ConnectX6-2p100GE.
        - s63-t34-sut2-c8/p2 - 100GE-port2 ConnectX6-2p100GE.
- TG [Server-Type-E32]:
    - testbedname: testbed34.
    - hostname: s64-t34-tg1.
    - IPMI IP: 10.30.50.74
    - Host IP: 10.30.51.74
    - portnames:
        - s64-t34-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
        - s64-t34-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
        - s64-t34-tg1-c4/p1 - 40GE-port1 xl710-QDA2-2p40GE.
        - s64-t34-tg1-c4/p2 - 40GE-port2 xl710-QDA2-2p40GE.
        - s64-t34-tg1-c8/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
        - s64-t34-tg1-c8/p2 - 100GE-port2 e810-2CQDA2-2p100GE.

3-Node-Icelake (3n-icx) #

- SUT1 [Server-Type-F3]:
    - testbedname: testbed37.
    - hostname: s65-t37-sut1.
    - IPMI IP: 10.30.50.75
    - Host IP: 10.30.51.75
    - portnames:
        - s65-t37-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
        - s65-t37-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
        - s65-t37-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
        - s65-t37-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
        - s65-t37-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
        - s65-t37-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
        - s65-t37-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
        - s65-t37-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
        - s65-t37-sut1-c10/p1 - 100GE-port1 ConnectX6-2p100GE.
        - s65-t37-sut1-c10/p2 - 100GE-port2 ConnectX6-2p100GE.
- SUT2 [Server-Type-F3]:
    - testbedname: testbed37.
    - hostname: s66-t37-sut2.
    - IPMI IP: 10.30.50.76
    - Host IP: 10.30.51.76
    - portnames:
        - s66-t37-sut2-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
        - s66-t37-sut2-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
        - s66-t37-sut2-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
        - s66-t37-sut2-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
        - s66-t37-sut2-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
        - s66-t37-sut2-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
        - s66-t37-sut2-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
        - s66-t37-sut2-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
        - s65-t37-sut1-c10/p1 - 100GE-port1 ConnectX6-2p100GE.
        - s65-t37-sut1-c10/p2 - 100GE-port2 ConnectX6-2p100GE.
- TG [Server-Type-F3]:
    - testbedname: testbed37.
    - hostname: s67-t37-tg1.
    - IPMI IP: 10.30.50.77
    - Host IP: 10.30.51.77
    - portnames:
        - s67-t37-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
        - s67-t37-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
        - s67-t37-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
        - s67-t37-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
        - s67-t37-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
        - s67-t37-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
        - s67-t37-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
        - s67-t37-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
        - s67-t37-tg1-c10/p1 - 100GE-port1 ConnectX6-2p100GE.
        - s67-t37-tg1-c10/p2 - 100GE-port2 ConnectX6-2p100GE.
- SUT1 [Server-Type-F3]:
    - testbedname: testbed38.
    - hostname: s78-t38-sut1.
    - IPMI IP: 10.30.50.78
    - Host IP: 10.30.51.78
    - portnames:
        - s78-t38-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
        - s78-t38-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
        - s78-t38-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
        - s78-t38-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
        - s78-t38-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
        - s78-t38-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
        - s78-t38-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
        - s78-t38-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
        - s78-t38-sut1-c10/p1 - 100GE-port1 ConnectX6-2p100GE.
        - s78-t38-sut1-c10/p2 - 100GE-port2 ConnectX6-2p100GE.
- SUT2 [Server-Type-F3]:
    - testbedname: testbed38.
    - hostname: s79-t38-sut2.
    - IPMI IP: 10.30.50.79
    - Host IP: 10.30.51.79
    - portnames:
        - s79-t38-sut2-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
        - s79-t38-sut2-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
        - s79-t38-sut2-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
        - s79-t38-sut2-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
        - s79-t38-sut2-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
        - s79-t38-sut2-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
        - s79-t38-sut2-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
        - s79-t38-sut2-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
        - s79-t38-sut2-c10/p1 - 100GE-port1 ConnectX6-2p100GE.
        - s79-t38-sut2-c10/p2 - 100GE-port2 ConnectX6-2p100GE.
- TG [Server-Type-F3]:
    - testbedname: testbed38.
    - hostname: s80-t38-tg1.
    - IPMI IP: 10.30.50.80
    - Host IP: 10.30.51.80
    - portnames:
        - s80-t38-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
        - s80-t38-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
        - s80-t38-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
        - s80-t38-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
        - s80-t38-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
        - s80-t38-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
        - s80-t38-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
        - s80-t38-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
        - s80-t38-tg1-c10/p1 - 100GE-port1 ConnectX6-2p100GE.
        - s80-t38-tg1-c10/p2 - 100GE-port2 ConnectX6-2p100GE.

3-Node-SnowRidge (3n-snr) #

- ServerG1 [Server-Type-G1]:
    - testbedname: testbed39.
    - hostname: s93-t39-sut1.
    - IPMI IP: 10.30.50.93
    - Host IP: 10.30.51.93
    - portnames:
        - s93-t39-sut1-c1/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
        - s93-t39-sut1-c1/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
        - s93-t39-sut1-c1/p2 - 25GE-port3 e810-XXVDA4-4p25GE.
        - s93-t39-sut1-c1/p2 - 25GE-port4 e810-XXVDA4-4p25GE.
- ServerG1 [Server-Type-G1]:
    - testbedname: testbed39.
    - hostname: s94-t39-sut2.
    - IPMI IP: 10.30.50.94
    - Host IP: 10.30.51.94
    - portnames:
        - s94-t39-sut2-c1/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
        - s94-t39-sut2-c1/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
        - s94-t39-sut2-c1/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
        - s94-t39-sut2-c1/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
- ServerC2 [Server-Type-C2]:
    - testbedname: testbed39.
    - hostname: s89-t39t310-tg1.
    - IPMI IP: 10.30.50.89
    - Host IP: 10.30.51.89
    - portnames:
        - s89-t39t310-tg1-c6/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
        - s89-t39t310-tg1-c6/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
        - s89-t39t310-tg1-c6/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
        - s89-t39t310-tg1-c6/p4 - 25GE-port4 e810-XXVDA4-4p25GE.

2-Node-SapphireRapids (2n-spr) #

- SUT [Server-Type-H1]:
    - testbedname: testbed21.
    - hostname: s52-t21-sut1.
    - IPMI IP: 10.30.50.52
    - Host IP: 10.30.51.52
    - portnames:
        - s52-t21-sut1-c10/p1 - 200GE-port1 ConnectX7-2p200GE.
        - s52-t21-sut1-c10/p2 - 200GE-port2 ConnectX7-2p200GE.
        - s52-t21-sut1-c4/p1 - 200GE-port1 ConnectX7-2p200GE.
        - s52-t21-sut1-c4/p2 - 200GE-port2 ConnectX7-2p200GE.
        - s52-t21-sut1-c2/p1 - 200GE-port1 ConnectX7-2p200GE.
        - s52-t21-sut1-c2/p2 - 200GE-port2 ConnectX7-2p200GE.
        - s52-t21-sut1-c9/p1 - 200GE-port1 ConnectX7-2p200GE.
        - s52-t21-sut1-c9/p2 - 200GE-port2 ConnectX7-2p200GE.
        - s52-t21-sut1-c7/p1 - 200GE-port1 ConnectX7-2p200GE.
        - s52-t21-sut1-c7/p2 - 200GE-port2 ConnectX7-2p200GE.
- TG [Server-Type-H2]:
    - testbedname: testbed21.
    - hostname: s53-t21-tg1.
    - IPMI IP: 10.30.50.53
    - Host IP: 10.30.51.53
    - portnames:
        - s53-t21-tg1-c10/p1 - 200GE-port1 ConnectX7-2p200GE.
        - s53-t21-tg1-c10/p2 - 200GE-port2 ConnectX7-2p200GE.
        - s53-t21-tg1-c4/p1 - 200GE-port1 ConnectX7-2p200GE.
        - s53-t21-tg1-c4/p2 - 200GE-port2 ConnectX7-2p200GE.
        - s53-t21-tg1-c2/p1 - 200GE-port1 ConnectX7-2p200GE.
        - s53-t21-tg1-c2/p2 - 200GE-port2 ConnectX7-2p200GE.
        - s53-t21-tg1-c9/p1 - 200GE-port1 ConnectX7-2p200GE.
        - s53-t21-tg1-c9/p2 - 200GE-port2 ConnectX7-2p200GE.
        - s53-t21-tg1-c7/p1 - 200GE-port1 ConnectX7-2p200GE.
        - s53-t21-tg1-c7/p2 - 200GE-port2 ConnectX7-2p200GE.
- SUT [Server-Type-H3]:
    - testbedname: testbed22.
    - hostname: s54-t22-sut1.
    - IPMI IP: 10.30.50.54
    - Host IP: 10.30.51.54
    - portnames:
        - s54-t22-sut1-c2/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
        - s54-t22-sut1-c2/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
        - s54-t22-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
        - s54-t22-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
        - s54-t22-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
        - s54-t22-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
        - s54-t22-sut1-c7/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
        - s54-t22-sut1-c7/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
        - s54-t22-sut1-c9/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
        - s54-t22-sut1-c9/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
        - s54-t22-sut1-c9/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
        - s54-t22-sut1-c9/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
- TG [Server-Type-H4]:
    - testbedname: testbed22.
    - hostname: s55-t22-tg1.
    - IPMI IP: 10.30.50.55
    - Host IP: 10.30.51.55
    - portnames:
        - s55-t22-tg1-c2/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
        - s55-t22-tg1-c2/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
        - s55-t22-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
        - s55-t22-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
        - s55-t22-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
        - s55-t22-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
- SUT [Server-Type-H5]:
    - testbedname: testbed23.
    - hostname: s56-t23-sut1.
    - IPMI IP: 10.30.50.56
    - Host IP: 10.30.51.56
    - portnames:
        - s56-t23-sut1-c2/p1 - 200GE-port1 ConnectX7-2p200GE.
        - s56-t23-sut1-c2/p2 - 200GE-port2 ConnectX7-2p200GE.
        - s56-t23-sut1-c4/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
        - s56-t23-sut1-c4/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
        - s56-t23-sut1-c10/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
        - s56-t23-sut1-c10/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
        - s56-t23-sut1-c10/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
        - s56-t23-sut1-c10/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
- TG [Server-Type-H6]:
    - testbedname: testbed23.
    - hostname: s57-t23-tg1.
    - IPMI IP: 10.30.50.57
    - Host IP: 10.30.51.57
    - portnames:
        - s57-t23-tg1-c2/p1 - 200GE-port1 ConnectX7-2p200GE.
        - s57-t23-tg1-c2/p2 - 200GE-port2 ConnectX7-2p200GE.
        - s57-t23-tg1-c4/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
        - s57-t23-tg1-c4/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
        - s57-t23-tg1-c10/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
        - s57-t23-tg1-c10/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
        - s57-t23-tg1-c10/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
        - s57-t23-tg1-c10/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
        - s57-t23-tg1-c7/p1 - 200GE-port1 ConnectX7-2p200GE.
        - s57-t23-tg1-c7/p2 - 200GE-port2 ConnectX7-2p200GE.
        - s57-t23-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
        - s57-t23-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
- SUT [Server-Type-H5]:
    - testbedname: testbed24.
    - hostname: s58-t24-sut1.
    - IPMI IP: 10.30.50.58
    - Host IP: 10.30.51.58
    - portnames:
        - s58-t24-sut1-c2/p1 - 200GE-port1 ConnectX7-2p200GE.
        - s58-t24-sut1-c2/p2 - 200GE-port2 ConnectX7-2p200GE.
        - s58-t24-sut1-c4/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
        - s58-t24-sut1-c4/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
        - s58-t24-sut1-c10/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
        - s58-t24-sut1-c10/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
        - s58-t24-sut1-c10/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
        - s58-t24-sut1-c10/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
- TG [Server-Type-H6]:
    - testbedname: testbed24.
    - hostname: s59-t24-tg1.
    - IPMI IP: 10.30.50.59
    - Host IP: 10.30.51.59
    - portnames:
        - s59-t24-tg1-c2/p1 - 200GE-port1 ConnectX7-2p200GE.
        - s59-t24-tg1-c2/p2 - 200GE-port2 ConnectX7-2p200GE.
        - s59-t24-tg1-c4/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
        - s59-t24-tg1-c4/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
        - s59-t24-tg1-c10/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
        - s59-t24-tg1-c10/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
        - s59-t24-tg1-c10/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
        - s59-t24-tg1-c10/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
        - s59-t24-tg1-c7/p1 - 200GE-port1 ConnectX7-2p200GE.
        - s59-t24-tg1-c7/p2 - 200GE-port2 ConnectX7-2p200GE.
        - s59-t24-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
        - s59-t24-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.

3-Node-IcelakeD (3n-icxd) #

- ServerI1 [Server-Type-I1]:
    - testbedname: testbed31.
    - hostname: s32-t31-sut1.
    - IPMI IP: 10.30.50.32
    - Host IP: 10.30.51.32
    - portnames:
        - s32-t31-sut1-c1/p1 - 25GE-port1 e822cq-2p25GE.
        - s32-t31-sut1-c1/p2 - 25GE-port2 e822cq-2p25GE.
- ServerI1 [Server-Type-I1]:
    - testbedname: testbed31.
    - hostname: s33-t31-sut2.
    - IPMI IP: 10.30.50.33
    - Host IP: 10.30.51.33
    - portnames:
        - s33-t31-sut2-c1/p1 - 25GE-port1 e822cq-2p25GE.
        - s33-t31-sut2-c1/p2 - 25GE-port2 e822cq-2p25GE.
- ServerF3 [Server-Type-F5]:
    - testbedname: testbed31.
    - hostname: s90-t31t32-tg1.
    - IPMI IP: 10.30.50.90
    - Host IP: 10.30.51.90
    - portnames:
        - s90-t31t32-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
        - s90-t31t32-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
        - s90-t31t32-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
        - s90-t31t32-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
- ServerI1 [Server-Type-I1]:
    - testbedname: testbed32.
    - hostname: s34-t32-sut1.
    - IPMI IP: 10.30.50.34
    - Host IP: 10.30.51.34
    - portnames:
        - s34-t32-sut1-c1/p1 - 25GE-port1 e822cq-2p25GE.
        - s34-t32-sut1-c1/p2 - 25GE-port2 e822cq-2p25GE.
- ServerI1 [Server-Type-I1]:
    - testbedname: testbed32.
    - hostname: s35-t32-sut2.
    - IPMI IP: 10.30.50.35
    - Host IP: 10.30.51.35
    - portnames:
        - s35-t32-sut2-c1/p1 - 25GE-port1 e822cq-2p25GE.
        - s35-t32-sut2-c1/p2 - 25GE-port2 e822cq-2p25GE.
- ServerF3 [Server-Type-F5]:
    - testbedname: testbed32.
    - hostname: s90-t31t32-tg1.
    - IPMI IP: 10.30.50.90
    - Host IP: 10.30.51.90
    - portnames:
        - s90-t31t32-tg1-c6/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
        - s90-t31t32-tg1-c6/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
        - s90-t31t32-tg1-c6/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
        - s90-t31t32-tg1-c6/p4 - 25GE-port4 e810-XXVDA4-4p25GE.

2-Node-Grace (2n-grc) #

- SUT [Server-Type-J1]:
    - testbedname: testbed27.
    - hostname: s36-t27-sut1.
    - IPMI IP: 10.30.50.36
    - Host IP: 10.30.51.36
    - portnames:
        - s36-t27-sut1-c1/p1 - 100GE-port1 ConnectX5-2p100GE.
        - s36-t27-sut1-c1/p2 - 100GE-port2 ConnectX5-2p100GE.
        - s36-t27-sut1-c2/p1 - 200GE-port1 ConnectX7-2p200GE.
        - s36-t27-sut1-c2/p2 - 200GE-port2 ConnectX7-2p200GE.
        - s36-t27-sut1-c3/p1 - 10GE-port1 x550T-2p10GE.
        - s36-t27-sut1-c3/p2 - 10GE-port1 x550T-2p10GE.
- TG [Server-Type-F6]:
    - testbedname: testbed27.
    - hostname: s37-t27-tg1.
    - IPMI IP: 10.30.50.37
    - Host IP: 10.30.51.37
    - portnames:
        - s37-t27-tg1-c2/p1 - 100GE-port1 ConnectX5-2p100GE.
        - s37-t27-tg1-c2/p2 - 100GE-port2 ConnectX5-2p100GE.
        - s37-t27-tg1-c4/p1 - 100GE-port1 ConnectX5-2p100GE.
        - s37-t27-tg1-c4/p2 - 100GE-port2 ConnectX5-2p100GE.
        - s37-t27-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
        - s37-t27-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.

Testbed Wiring #

1-Node-Altra (1n-alt) #

- testbed13:
    - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
        - s70-t13-sut1-c0/p1 - s70-t13-sut1-c3/p1.
    - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
        - s70-t13-sut1-c0/p2 - s70-t13-sut1-c3/p2.
    - ring3 100GE-ports ConnectX6-2p100GE on SUTs:
        - s70-t13-sut1-c1/p1 - s70-t13-sut1-c1/p2.
    - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
        - s70-t13-sut1-c2/p1 - s70-t13-sut1-c5/p1.
    - ring5 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
        - s70-t13-sut1-c2/p2 - s70-t13-sut1-c5/p2.

- testbed14:
    - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
        - s71-t14-sut1-c0/p1 - s71-t14-sut1-c3/p1.
    - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
        - s71-t14-sut1-c0/p2 - s71-t14-sut1-c3/p2.
    - ring3 100GE-ports ConnectX6-2p100GE on SUTs:
        - s71-t14-sut1-c1/p1 - s71-t14-sut1-c1/p2.
    - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
        - s71-t14-sut1-c2/p1 - s71-t14-sut1-c5/p1.
    - ring5 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
        - s71-t14-sut1-c2/p2 - s71-t14-sut1-c5/p2.

1-Node-SapphireRapids (1n-spr) #

- testbed15:
    - ring1 100GE-ports e810-2p100GE:
        - s30-t15-sut1-c1/p1 to s30-t15-sut1-c2/p1.
    - ring2 100GE-ports e810-2p100GE:
        - s30-t15-sut1-c1/p2 to s30-t15-sut1-c2/p2.
    - ring3 10GE-ports x710-4p10GE:
        - s30-t15-sut1-c7/p1 to s30-t15-sut1-c9/p1.
    - ring4 10GE-ports x710-4p10GE:
        - s30-t15-sut1-c7/p2 to s30-t15-sut1-c9/p2.
    - ring5 10GE-ports x710-4p10GE:
        - s30-t15-sut1-c7/p3 to s30-t15-sut1-c9/p3.
    - ring6 10GE-ports x710-4p10GE:
        - s30-t15-sut1-c7/p4 to s30-t15-sut1-c9/p4.
- testbed16:
    - ring1 100GE-ports e810-2p100GE:
        - s31-t16-sut1-c1/p1 to s31-t16-sut1-c2/p1.
    - ring2 100GE-ports e810-2p100GE:
        - s31-t16-sut1-c1/p2 to s31-t16-sut1-c2/p2.
    - ring3 10GE-ports x710-4p10GE:
        - s31-t16-sut1-c9/p1 to s31-t16-sut1-c9/p1.
    - ring4 10GE-ports x710-4p10GE:
        - s31-t16-sut1-c9/p2 to s31-t16-sut1-c9/p2.
    - ring5 10GE-ports x710-4p10GE:
        - s31-t16-sut1-c9/p3 to s31-t16-sut1-c9/p3.
    - ring6 10GE-ports x710-4p10GE:
        - s31-t16-sut1-c9/p4 to s31-t16-sut1-c9/p4.

2-Node-Zen2 (2n-zn2) #

- testbed210:
    - ring1 10GE-ports x710-4p10GE on SUT:
        - s61-t210-tg1-c2/p1 to s60-t210-sut1-c1/p1.
        - s60-t210-sut1-c1/p2 to s61-t210-tg1-c2/p2.
    - ring2 10GE-ports x710-4p10GE on SUT:
        - s61-t210-tg1-c2/p3 to s60-t210-sut1-c1/p3.
        - s60-t210-sut1-c1/p4 to s61-t210-tg1-c2/p4.
    - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
        - s61-t210-tg1-c3/p1 to s60-t210-sut1-c2/p1.
        - s60-t210-sut1-c2/p2 to s61-t210-tg1-c3/p2.
    - ring4 100GE-ports ConnectX5-2p100GE on SUT:
        - s61-t210-tg1-c1/p1 to s60-t210-sut1-c3/p1.
        - s60-t210-sut1-c3/p2 to s61-t210-tg1-c1/p2.

2-Node-Icelake (2n-icx) #

- testbed212:
    - ring1 25GE-ports xxv710-DA2-2p25GE:
        - s72-t212-tg1-c2/p1 to s71-t212-sut1-c2/p1.
        - s71-t212-sut1-c2/p2 to s72-t212-tg1-c2/p2.
    - ring2 25GE-ports e810-XXVDA4-2p25GE:
        - s72-t212-tg1-c4/p1 to s71-t212-sut1-c4/p1.
        - s71-t212-sut1-c4/p2 to s72-t212-tg1-c4/p2.
        - s72-t212-tg1-c4/p3 to s71-t212-sut1-c4/p3.
        - s71-t212-sut1-c4/p4 to s72-t212-tg1-c4/p4.
    - ring3 100GE-ports e810-2CQDA2-2p100GE:
        - s72-t212-tg1-c9/p1 to s71-t212-sut1-c9/p1.
        - s71-t212-sut1-c9/p2 to s72-t212-tg1-c9/p2.
    - ring4 100GE-ports e810-2CQDA2-2p100GE:
        - s72-t212-tg1-c6/p1 to s72-t212-tg1-c6/p2.
        - s72-t212-tg1-c6/p2 to s72-t212-tg1-c6/p1.
    - ring5 200GE-ports ConnectX7-2p200GE:
        - s72-t212-tg1-c8/p1 to s71-t212-sut1-c8/p1.
        - s71-t212-sut1-c8/p2 to s72-t212-tg1-c8/p2.
- testbed213:
    - ring1 25GE-ports xxv710-DA2-2p25GE:
        - s84-t213-tg1-c2/p1 to s83-t213-sut1-c2/p1.
        - s83-t213-sut1-c2/p2 to s84-t213-tg1-c2/p2.
    - ring2 25GE-ports e810-XXVDA4-2p25GE:
        - s84-t213-tg1-c4/p1 to s83-t213-sut1-c4/p1.
        - s83-t213-sut1-c4/p2 to s84-t213-tg1-c4/p2.
        - s84-t213-tg1-c4/p3 to s83-t213-sut1-c4/p3.
        - s83-t213-sut1-c4/p4 to s84-t213-tg1-c4/p4.
    - ring3 100GE-ports e810-2CQDA2-2p100GE:
        - s84-t213-tg1-c9/p1 to s83-t213-sut1-c9/p1.
        - s83-t213-sut1-c9/p2 to s84-t213-tg1-c9/p2.
    - ring4 100GE-ports e810-2CQDA2-2p100GE:
        - s84-t213-tg1-c6/p1 to s84-t213-tg1-c6/p2.
        - s84-t213-tg1-c6/p2 to s84-t213-tg1-c6/p1.
    - ring5 200GE-ports ConnectX7-2p200GE:
        - s84-t213-tg1-c8/p1 to s83-t213-sut1-c8/p1.
        - s83-t213-sut1-c8/p2 to s84-t213-tg1-c8/p2.
- testbed214:
    - ring1 25GE-ports xxv710-DA2-2p25GE:
        - s86-t214-tg1-c2/p1 to s85-t214-sut1-c2/p1.
        - s85-t214-sut1-c2/p2 to s86-t214-tg1-c2/p2.
    - ring2 25GE-ports e810-XXVDA4-2p25GE:
        - s86-t214-tg1-c4/p1 to s85-t214-sut1-c4/p1.
        - s85-t214-sut1-c4/p2 to s86-t214-tg1-c4/p2.
        - s86-t214-tg1-c4/p3 to s85-t214-sut1-c4/p3.
        - s85-t214-sut1-c4/p4 to s86-t214-tg1-c4/p4.
    - ring3 100GE-ports e810-2CQDA2-2p100GE:
        - s86-t214-tg1-c9/p1 to s85-t214-sut1-c9/p1.
        - s85-t214-sut1-c9/p2 to s86-t214-tg1-c9/p2.
    - ring4 100GE-ports e810-2CQDA2-2p100GE:
        - s86-t214-tg1-c6/p1 to s86-t214-tg1-c6/p2.
        - s86-t214-tg1-c6/p2 to s86-t214-tg1-c6/p1.
    - ring5 200GE-ports ConnectX7-2p200GE:
        - s86-t214-tg1-c8/p1 to s85-t214-sut1-c8/p1.
        - s85-t214-sut1-c8/p2 to s86-t214-tg1-c8/p2.

2-Node-Icelake (2n-oct) #

- testbed215:
    - ring1 25GE-ports xxv710-DA2-2p25GE:
        - s88-t215-tg1-c2/p1 to s87-t215-sut1-c2/p1.
        - s87-t215-sut1-c2/p2 to s88-t215-tg1-c2/p2.
    - ring2 25GE-ports e810-XXVDA4-2p25GE:
        - s88-t215-tg1-c4/p1 to s87-t215-sut1-c4/p1.
        - s87-t215-sut1-c4/p2 to s88-t215-tg1-c4/p2.
        - s88-t215-tg1-c4/p3 to s87-t215-sut1-c4/p3.
        - s87-t215-sut1-c4/p4 to s88-t215-tg1-c4/p4.
    - ring3 100GE-ports e810-2CQDA2-2p100GE:
        - s88-t215-tg1-c9/p1 to s87-t215-sut1-c9/p1.
        - s87-t215-sut1-c9/p2 to s88-t215-tg1-c9/p2.
    - ring4 100GE-ports e810-2CQDA2-2p100GE:
        - s88-t215-tg1-c6/p1 to s88-t215-tg1-c6/p2.
        - s88-t215-tg1-c6/p2 to s88-t215-tg1-c6/p1.
    - ring5 200GE-ports ConnectX7-2p200GE:
        - s88-t215-tg1-c8/p1 to s87-t215-sut1-c8/p1.
        - s87-t215-sut1-c8/p2 to s88-t215-tg1-c8/p2.

3-Node-Altra (3n-alt) #

- testbed34:
    - ring1 40GE-ports xl710-QDA2-2p40GE on SUTs:
        - s64-t34-tg1-c4/p1 - s62-t34-sut1-c1/p2.
        - s62-t34-sut1-c1/p1 - s63-t34-sut2-c1/p2.
        - s63-t34-sut2-c1/p1 - s64-t34-tg1-c4/p2.
    - ring2 100GE-ports ConnectX6-2p100GE Mellanox on SUTs:
        - s64-t34-tg1-c8/p1 - s62-t34-sut2-c8/p1.
        - s62-t34-sut1-c8/p1 - s63-t34-sut2-c8/p2.
        - s63-t34-sut1-c8/p2 - s64-t34-tg1-c8/p2.

3-Node-Icelake (3n-icx) #

- testbed37:
    - ring1 25GE-ports xxv710-DA2-2p25GE:
        - s67-t37-tg1-c2/p1 to s65-t37-sut1-c2/p1.
        - s65-t37-sut1-c2/p2 to s66-t37-sut2-c2/p2.
        - s66-t37-sut2-c2/p1 to s67-t37-tg1-c2/p2.
    - ring2 25GE-ports e810-XXVDA4-4p25GE:
        - s67-t37-tg1-c4/p1 to s65-t37-sut1-c4/p1.
        - s65-t37-sut1-c4/p2 to s66-t37-sut2-c4/p2.
        - s66-t37-sut2-c4/p1 to s67-t37-tg1-c4/p2.
        - s67-t37-tg1-c4/p3 to s65-t37-sut1-c4/p3.
        - s65-t37-sut1-c4/p4 to s66-t37-sut2-c4/p4.
        - s66-t37-sut2-c4/p3 to s67-t37-tg1-c4/p4.
    - ring3 100GE-ports e810-2CQDA2-2p100GE:
        - s67-t37-tg1-c9/p1 to s65-t37-sut1-c9/p1.
        - s65-t37-sut1-c9/p2 to s66-t37-sut2-c9/p2.
        - s66-t37-sut2-c9/p1 to s67-t37-tg1-c9/p2.
    - ring4 200GE-ports ConnectX6-2p200GE:
        - s67-t37-tg1-c10/p1 - s65-t37-sut1-c10/p2.
        - s65-t37-sut1-c10/p1 - s66-t37-sut2-c10/p2.
        - s66-t37-sut2-c10/p1 - s67-t37-tg1-c10/p2.
- testbed38:
    - ring1 25GE-ports xxv710-DA2-2p25GE:
        - s80-t38-tg1-c2/p1 to s78-t38-sut1-c2/p1.
        - s78-t38-sut1-c2/p2 to s79-t38-sut2-c2/p2.
        - s79-t38-sut2-c2/p1 to s80-t38-tg1-c2/p2.
    - ring2 25GE-ports e810-XXVDA4-4p25GE:
        - s80-t38-tg1-c4/p1 to s78-t38-sut1-c4/p1.
        - s78-t38-sut1-c4/p2 to s79-t38-sut2-c4/p2.
        - s79-t38-sut2-c4/p1 to s80-t38-tg1-c4/p2.
        - s80-t38-tg1-c4/p3 to s78-t38-sut1-c4/p3.
        - s78-t38-sut1-c4/p4 to s79-t38-sut2-c4/p4.
        - s79-t38-sut2-c4/p3 to s80-t38-tg1-c4/p4.
    - ring3 100GE-ports e810-2CQDA2-2p100GE:
        - s80-t38-tg1-c9/p1 to s78-t38-sut1-c9/p1.
        - s78-t38-sut1-c9/p2 to s79-t38-sut2-c9/p2.
        - s79-t38-sut2-c9/p1 to s80-t38-tg1-c9/p2.
    - ring4 200GE-ports ConnectX6-2p200GE:
        - s80-t38-tg1-c10/p1 to s78-t38-sut1-c10/p1.
        - s78-t38-sut1-c10/p2 to s79-t38-sut2-c10/p2.
        - s79-t38-sut2-c10/p1 to s80-t38-tg1-c10/p2.

3-Node-SnowRidge (3n-snr) #

- testbed39:
    - ring1 25GE-ports e810-XXVDA4-4p25GE:
        - s89-t39t310-tg1-c6/p1 to s93-t39-sut1-c1/p1.
        - s93-t39-sut1-c1/p2 to s94-t39-sut2-c1/p2.
        - s94-t39-sut2-c1/p1 to s89-t39t310-tg1-c6/p2.
        - s89-t39t310-tg1-c6/p3 to s93-t39-sut1-c1/p3.
        - s93-t39-sut1-c1/p4 to s94-t39-sut2-c1/p4.
        - s94-t39-sut2-c1/p3 to s89-t39t310-tg1-c6/p4.

2-Node-SapphireRapids (2n-spr) #

- testbed21:
    - ring1 200GE-ports ConnectX7-2p200GE:
        - s53-t21-tg1-c2/p1 to s52-t21-sut1-c2/p1
        - s53-t21-tg1-c7/p1 to s52-t21-sut1-c7/p1
        - s52-t21-sut1-c4/p2 to s52-t21-sut1-c9/p2
    - ring2 200GE-ports ConnectX7-2p200GE:
        - s53-t21-tg1-c2/p2 to s52-t21-sut1-c2/p2
        - s53-t21-tg1-c7/p2 to s52-t21-sut1-c7/p2
        - s52-t21-sut1-c10/p1 to s52-t21-sut1-c11/p1
    - ring3 200GE-ports ConnectX7-2p200GE:
        - s53-t21-tg1-c4/p1 to s52-t21-sut1-c4/p1
        - s53-t21-tg1-c9/p1 to s52-t21-sut1-c9/p1
        - s52-t21-sut1-c10/p2 to s52-t21-sut1-c11/p2
- testbed22:
    - ring1 100GE-ports e810-2CQDA2-2p100GE:
        - s55-t22-tg1-c4/p1  to s54-t22-sut1-c9/p2
        - s55-t22-tg1-c4/p2  to s54-t22-sut1-c4/p2
        - s54-t22-sut1-c9/p1 to s54-t22-sut1-c4/p1
    - ring2 25GE-ports e810-XXVDA4-4p25GE:
        - s55-t22-tg1-c2/p1  to s54-t22-sut1-c2/p1
        - s55-t22-tg1-c2/p2  to s54-t22-sut1-c7/p1
        - s54-t22-sut1-c2/p2 to s54-t22-sut1-c7/p2
- testbed23:
    - ring1 200GE-ports ConnectX7-2p200GE:
        - s56-t23-sut1-c2/p1 to s57-t23-tg1-c2/p1.
        - s57-t23-tg1-c2/p2 to s56-t23-sut1-c2/p2.
    - ring2 100GE-ports e810-2CQDA2-2p100GE:
        - s56-t23-sut1-c4/p1 to s57-t23-tg1-c4/p1.
        - s57-t23-tg1-c4/p2 to s56-t23-sut1-c4/p2.
    - ring3 25GE-ports e810-XXVDA4-4p25GE:
        - s56-t23-sut1-c10/p1 to s57-t23-tg1-c10/p1.
        - s56-t23-sut1-c10/p2 to s57-t23-tg1-c10/p2.
        - s56-t23-sut1-c10/p3 to s57-t23-tg1-c10/p3.
        - s56-t23-sut1-c10/p4 to s57-t23-tg1-c10/p4.
    - ring4 200GE-ports ConnectX7-2p200GE:
        - s57-t23-tg1-c7/p1 to s57-t23-tg1-c7/p2.
    - ring5 100GE-ports e810-2CQDA2-2p100GE:
        - s57-t23-tg1-c9/p1 to s57-t23-tg1-c9/p2.
- testbed24:
    - ring1 200GE-ports ConnectX7-2p200GE:
        - s58-t24-sut1-c2/p1 to s59-t24-tg1-c2/p1.
        - s59-t24-tg1-c2/p2 to s58-t24-sut1-c2/p2.
    - ring2 100GE-ports e810-2CQDA2-2p100GE:
        - s58-t24-sut1-c4/p1 to s59-t24-tg1-c4/p1.
        - s59-t24-tg1-c4/p2 to s58-t24-sut1-c4/p2.
    - ring3 25GE-ports e810-XXVDA4-4p25GE:
        - s58-t24-sut1-c10/p1 to s59-t24-tg1-c10/p1.
        - s58-t24-sut1-c10/p2 to s59-t24-tg1-c10/p2.
        - s58-t24-sut1-c10/p3 to s59-t24-tg1-c10/p3.
        - s58-t24-sut1-c10/p4 to s59-t24-tg1-c10/p4.
    - ring4 200GE-ports ConnectX7-2p200GE:
        - s59-t24-tg1-c7/p1 to s59-t24-tg1-c7/p2.
    - ring5 100GE-ports e810-2CQDA2-2p100GE:
        - s59-t24-tg1-c9/p1 to s59-t24-tg1-c9/p2.

3-Node-IcelakeD (3n-icxd) #

- testbed31:
    - ring1 25GE-ports e822cq-2p25GE:
        - s90-t31t32-tg1-c4/p1 to s32-t31-sut1-c1/p1.
        - s32-t31-sut1-c1/p2 to s33-t31-sut2-c1/p2.
        - s33-t31-sut2-c1/p1 to s90-t31t32-tg1-c4/p2.
- testbed32:
    - ring1 25GE-ports e822cq-2p25GE:
        - s90-t31t32-tg1-c6/p1 to s34-t32-sut1-c1/p1.
        - s34-t32-sut1-c1/p2 to s35-t32-sut2-c1/p2.
        - s35-t32-sut2-c1/p1 to s90-t31t32-tg1-c6/p2.

2-Node-GraceServer (2n-grc) #

- testbed27:
    - ring1 100GE-ports ConnectX5-2p100GE:
        - s37-t27-tg1-c9/p1 to s36-t27-sut1-c1/p1.
        - s36-t27-sut1-c1/p2 to s37-t27-tg1-c9/p2.
    #- ring2 200GE-ports ConnectX7-2p200GE:
    #    - s37-t27-tg1-c2/p1 to s36-t27-sut1-c1/p1.
    #    - s36-t27-sut1-c1/p2 to s37-t27-tg1-c2/p2.